Secure SRT321 User And Installation Instructions Manual page 17

Electronic room thermostat & temperature sensor (tx) - z-wave
Hide thumbs Also See for SRT321:
Table of Contents

Advertisement

Basic Command Class
Battery Level
Command Class
Wake Up Command
Class (Ver 2)
Thermostat Set Point
Command Class
This command class is not supported
Provides the current battery voltage level Battery
Level Reports and Low Battery Warnings
(Battery Level Reports with parameter = 0xFF)
can be sent unsolicited to nodes in Group 3.
Wake Up Commands are available through the
'Wake Up Capabilities Report'. Default wakeup
settings will be used if the unit is not included
onto a network or has not received a valid wake
up interval.
Set Point type of Heating is supported.
The SRT321 will accept Set Point SET
commands if the set point type matches the
thermostat type configuration.
SRT321 will send a Set Point REPORT in
response to a Set Point GET message or
unsolicited message can be sent to nodes in
Group 4 when the set temperature is changed
locally on the SRT321.
Continued on next page...