Operation; Your First Fire; Pilot And Burner Inspection; Flame & Temperature Adjustment - Vermont Castings INDVRCBSB Installation And Operating Instructions Manual

Intrepid direct vent gas heater
Table of Contents

Advertisement

The Intrepid is operated with the operable door front plate
in place with the doors open or closed. To open the front
doors, pull either door toward you.

Your First Fire

Read these instructions carefully and familiarize yourself
with the burner controls shown in Figure 63. Locate the
pilot assembly, Figure 64. Follow the lighting instructions
on exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within a few hours. You can open
a window to provide fresh air to alleviate the condition.
Manifold Pressure Tap
Pilot Adjustment
Screw
Fig. 63 NOVA SIT valve control.
ST941
SIT valve
6/07
Pilot Assembly
Fig. 64 Pilot Assembly location.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame
and burner flame pattern are as shown in Figure 66. If
flame patterns are incorrect, turn the heater off. Contact
your dealer or a qualified gas technician for assistance.
Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on
page 37.
20306761
Inlet Pressure Tap
Gas Control
Regulator
Knob
Control Knob
ST935
SDDVT
pilot location
6/07
Intrepid® Direct Vent - Rear Vent Gas Heater

Operation

Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjustment
is accomplished by rotating the HI/LO adjustment knob
located near the center of the gas control valve. (Fig. 65)
It is important to periodically perform a visual check of the
pilot and the burner flames. Compare them to Figure 66. If
any of the flames appear abnormal call a service person.
Turn
counterclockwise
to increase
flame height
Fig. 65 Flame adjustment knob for SIT valve.
PSE Pilot
ST941
ST233
Fig. 66 Correct pilot and burner flame patterns.
pilot
12/9/99 djt
On/Off and Hi/Lo control knob extensions have been in-
cluded in the finish bag. These may be installed on the
appropriate knob by aligning the notch on the existing
knob (Fig. 63) with the tab on the inside of the extension
knob (Fig. 67) Push the extension knob as far as it will go
onto the existing knob.
Fig. 67 Extension knob.

Flame Characteristics

Turn clockwise
FP390
FLAME ADJUSTMENT KNOB
11/21/96
SIT Pilot

Extension Knobs

CO105d
LG500
Pilot flame
Intrepid log flames
7/07
6/07 djt
Tab - align with notch
on existing knob
ST972
to decrease
flame height
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

IndvrbssbIndvrbmsbIndvrbdsb

Table of Contents