Connect Optional Remote Receiver; Checking System Operation - Vermont Castings EYF18 Installation And Operating Instructions Manual

Gas log set eyf series
Table of Contents

Advertisement

ELECTRICAL WIRING - MILLIVOLT
CONNECTING OPTIONAL REMOTE RE-
CEIVER
FOLLOW INSTRUCTIONS SUPPLIED WITH
THE REMOTE
1. Connect the wires to the two .25" male connectors
located on the left side of the valve when facing the
unit. Page 12, Figure 15. Do not let wire touch grate or
burner.
2. Stick velcro pads with self-adhesive backing to the right
side of remote receiver and to the left side of the unit.
Figure 16
. Attach remote receiver with velcro pads. Control switch
must face forward.
NOTE: Heat reduces battery life. You can protect the
receiver and extend battery life by mounting the receiver
in a wall or other location outside the fireplace.
Check
Test
To Test
A
Complete
System
B
Thermopile
Output
Remote
Receiver
Figure 16 -
Install Remote Receiver
65D1009
Connect
Switch or
Meter Leads
Thermostat
To Terminals
Contacts
2 & 
Closed
1 & 2
Open
Velcro
Pads
FP2540
install remote receiver
EYF Series Unvented Gas Log Set

CHECkING SYSTEM OPERATION

The millivolt system and individual components may be
checked with a millivolt meter having a 1-1000 mV range.
Conduct each check shown in chart by connecting meter
test leads to terminals as indicated.
A. Complete Millivolt System Check
("A" Reading - Thermostat contacts CLOSED - Control
knob "ON" - Main burner should turn ON)
1. If reading is more than 175 millivolts and the au-
tomatic valve still does not come on, replace the
control.
2. If the closed circuit reading ("A" reading) is less
than 175 millivolts, determine cause for low read-
ing, proceed to Section B.
B. Thermopile Output Reading Check
("B" Reading - thermostat contacts OPEN - Main burn-
er OFF
1. Check gas pressure to the unit. If gas pressure is
within minimum and maximum on data plate, then
check pilot voltage, 500 millivolts minimum. If the
minimum millivolt reading is not obtainable, replace
pilot.
Meter
Reading
Should Be
Minimum 175
Minimum 500
L O
H I
O F
F
FP2540
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eyf24