Intrepid® Direct Vent - Rear Vent Gas Heater

Operation

The Intrepid is operated with the operable door front plate in
place with the doors open or closed. To open the front doors,
pull either door toward you.

Your First Fire

Read these instructions carefully and familiarize yourself
with the burner controls shown in Figure 63. Locate the pilot
assembly, Figure 64. Follow the lighting instructions on exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within a few hours. You can open a
window to provide fresh air to alleviate the condition.
Manifold Pressure Tap
Pilot Adjustment
Screw
Figure 63 - NOVA SIT valve control.
Pilot Assembly
Figure 64 - Pilot Assembly location.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame
and burner flame pattern are as shown in Figure 66. If flame
patterns are incorrect, turn the heater off. Contact your dealer
or a qualified gas technician for assistance. Do not operate
the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on
page 37.
3-90-20306761
Inlet Pressure Tap
Gas Control
Regulator
Knob
Control Knob
ST941
SIT valve
6/07
ST935
SDDVT
pilot location
6/07
Vermont Castings • Intrepid DV Owner's Manual_R3 • 12/16
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjustment is
accomplished by rotating the HI/LO adjustment knob located
near the center of the gas control valve. (Figure 65)

Flame Characteristics

It is important to periodically perform a visual check of the
pilot and the burner flames. Compare them to Figure 66. If
any of the flames appear abnormal call a service person.
Turn
counterclockwise
to increase
flame height
Figure 65 - Flame adjustment knob for SIT valve.
PSE Pilot
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Figure 66 - Correct pilot and burner flame patterns.
ST233
Extension Knobs
pilot
On/Off and Hi/Lo control knob extensions have been
12/9/99 djt
included in the finish bag. These may be installed on the
appropriate knob by aligning the notch on the existing knob
(Figure 63) with the tab on the inside of the extension knob
(Figure 67) Push the extension knob as far as it will go onto
the existing knob.
Tab - align with notch on existing knob
Figure 67 - Extension knob.
ST972

extension knobs

7/07
Turn clockwise
to decrease
flame height
SIT Pilot
CO105d
Pilot flame
LG500
Intrepid log flames
6/07 djt