E.C.A. Fortius Service Manual page 4

24 kw open flued gas combination boiler (bithermic type) 24 kw room sealed fan assisted gas combination boiler (bithermic type) 24 kw room sealed fan assisted gas combination boiler (monothermic type) 28 kw room sealed fan assisted gas combination boil
Table of Contents

Advertisement

Table 2
Gas Category*
Boiler Type
Type of gas
Performances
P
, Min. Heat Output
min
P
, Max. Heat Output
maks
P
, Heat Output
%80
Q
, Min. Thermal Load
min
Q
, Max. Thermal Load
maks
Q
, Thermal Load
%80
Gas Consumption**
Natural Gas (Max. Load)
Natural Gas (Min. Load)
LPG
Gas Supply Pressure
Natural Gas
LPG
Domestic Hot Water
Min. Flow Rate For Activating
Max. Flow Rate
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
Central Heating
Min. Operating Pressure
Max. Operating Pressure
Set Temperature Range
General
Electrical Supply
Electrical Power Consumption
Expansion Vessel
Dimensions (HxWxL)
Weight (Net)
**For gas consumption calculation ; Natural gas: Hu=9,59 kWh/m
*** DHW ON flow rate can be adjustable as 3 ltr/min (default) or 3,5 ltr/min.
*the following gas categories can also be used
Gas Categories
FO 24 BB
II
2H 3+
B
11 BS
Natural gas
LPG
8,4
24
19,2
9,3
26,6
21,3
2,77
0,97
2,08
20
28 / 37
***
3
10 (∆t=34)
0,3
10
35-60
0,8
3
40-80
230V AC- 50Hz
105
8
750x454x340
750x454x340
33,7
LPG: Hu=12,793 kWh/kg
FO 24 BB
II
2H 3B/P
II
2E 3B/P
FO 24 HB
FO 24 HM
II
II
2H 3+
2H 3+
C
, C
C
12x
32
12x
Natural gas
Natural gas
LPG
LPG
8,4
8,4
24
24
19,2
19,2
9,2
9,2
26,2
26,2
21
21
2,73
2,73
0,96
0,96
2,08
2,08
20
20
28 / 37
28 / 37
3
10 (∆t=34)
10 (∆t=34)
0,3
0,3
10
10
35-60
35-60
0,8
0,8
3
40-80
40-80
230V AC- 50Hz
230V AC- 50Hz
150
150
8
750x454x340
39,8
40,8
3
FO 24 HB
II
2H 3B/P
II
2E 3B/P
FO 28 HM
II
2H 3+
, C
C
, C
32
12x
32
Natural gas
LPG
9,8
28
22,4
10,7
30,6
24,5
3,19
1,12
2,39
20
28 / 37
3
3
12 (∆t=33)
0,3
10
35-60
0,8
3
3
40-80
230V AC- 50Hz
150
8
8
750x454x340
41,3
FO 24 HM
FO 28 HM
II
II
2H 3B/P
II
II
2E 3B/P
Unit
kW
kW
kW
kW
kW
kW
3
m
/h
3
m
/h
kg/h
mbar
mbar
ltr/min
ltr/min
bar
bar
o
C
bar
bar
o
C
V AC/Hz
watt
ltr
mm
kg
2H 3B/P
2E 3B/P
3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fortius and is the answer not in the manual?

Table of Contents