Download Print this page

Electrical Specifications - Phono Solar PowerHub 1800 Installation Manual

Solar generator

Advertisement

Electrical Specifications

Electrical Specifications for the Inverter
Parameter
Maximum Output Power
Continuous Output Power
Surge Rating
Input Voltage Range
Input Frequency Range
Peak Efficiency
System Shutdown Mode
(Display On)
Idle Mode
Output Frequency
Output Waveform (resistive load) Modified sine wave (>30% THD)
Output Voltage (at no load)
Low Battery Cutout
High Battery Cutout
Transfer Relay Rating
Transfer Time AC to Inverter
AC Qualification Time
Protection
Electrical Specifications for the Battery Box
Parameter
Protection
1.Stand-alone battery box Xantrex Part Number: PH1800-BBX
Specifications
PowerHub 1800 Inverter
1800 W (15A) (5 minutes maximum)
1440 W (12 A)
2880 W (24 A)
10.5 to 15.0 Vdc
60 Hz
88%
< 12 W
<1.5 W
60 Hz / ±1 Hz
110 to 125 Vac
10.5 Vdc with < 240 W load and 11.0 V with > 240 W load
15.0 Vdc
20 A
< 40 ms
~ 20 seconds
Five 20 A/32 Vdc fuses protecting the 80A/1000 W DC input
terminal.
Two 20 A/32 Vdc fuses protecting 32A/ 400 W DC input
terminal.
One 15 Aac supplemental protector.
One 1 A/250 Vac fuse for system ground fault protection.
1
Battery Box
Ten 20 A/32 Vdc Fuses for short circuit and reverse polarity
conditions.
62

Advertisement

loading