Download Print this page

Phono Solar PowerHub 1800 Installation Manual page 43

Solar generator

Advertisement

Recommended Wire Gauges for Input and Output Terminals
Terminal
AC Input (Neutral and Line)
AC Output (Neutral and Line)
AC Ground
DC Input (32 A DC Input/40 A fused)
DC Input (80 A DC Input/100 A fused)
DC Ground
System Ground
Removing the Factory-installed AC Cord and Knockouts
Removing the AC Cord
Installation
Acceptable Wire Gauge
#14 AWG
#14 AWG
#14 AWG
Manufacturer's recommendation.
Manufacturer's recommendation.
Manufacturer's recommendation.
#3 AWG
1. Locate the AC wiring from the
cord and loosen the screws on
the Ground, Line 1 (L1), and
Neutral terminals.
2. Remove the 3 #6-32
Phillips screws on the AC
cord access plate and
remove the plate along
with the cord.
42
Torque to.....
1.3 Nm (11.5 in-lbs)
1.3 Nm (11.5 in-lbs)
1.8 Nm (16.0 in-lbs)
20.3 Nm (180 in-lbs)
20.3 Nm (180 in-lbs)
20.3 Nm (180 in-lbs)
Proceed to Figure
.

Advertisement

loading