Download Print this page

Installation Instructions - Gabarron ADL 5030 Installation Instructions And User Manual

Gabarron dynamic storage heaters

Advertisement

Dynamic Storage Heaters
The input control operates a highly sensitive thermostat which regulates the amount of heat stored.
The discharge takes place when the built-in blower operates. The blower drives fresh air through the core and is heated.
A bimetallic device mixes the hot air with fresh air to provide homogeneous temperature.
It is important that the correct rating of heater is installed to provide the selected level of heat. This will ensure the best
possible running costs against other fuels.
To avoid transport problems, the heater casings and storage bricks are packed separately. The bricks with some slight
defects in the corners can be used.
You should be aware that storage heaters, when fully charged, can have high surface temperatures.

2.- INSTALLATION INSTRUCTIONS

Please follow these instructions for a properly installation.
1.- Chose the right place to install the heater, considering the minimum distances between heater and other objects. It is
needed a minimum distance of 50 cm to assure a good heat delivery.
2.- Open the carton box by the indicated side, and remove the box containing the accessories, electrical elements and
parts to fix to the wall. Turn upside down the box so the heater stands up on its feet and remove the shipping carton.
Check the type is the asked and it is O.K.
3.- Screw on the wall the fixing part, making drills at 61 cm over de floor (Fig. 1).
fig. 1
This device prevents the heater overturning when a force of up to 20kg is applied to the upper parts to the exterior. The
function of the device is not to hang the heater. If there is any doubt as to the strength of the wall, please consult an
expert. Storage heaters are very heavy and the installer must ensure that they are securely fixed and there is no
possibility of them overturning.
4.- Remove the front outlet grill by removing the four screws. Remove also the front panel by removing the two screws at
the bottom of the heater.
3

Advertisement

loading

This manual is also suitable for:

Adl 4024Adl 3018Adl 2012