Wiring Diagram (Code 10220 - Lincoln Electric CLASSICII SVM125-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

G-7

Wiring Diagram (Code 10220)

ENGINE
FAILURE
LAMP
ENGINE
HOUR
METER
START
-
+
58A
60
50A
52
STARTING
MOTOR
+
REMOTE CONTROL RECEPTACLE & SWITCH
*
B
SEE
BELOW
R
1
41
2
600
*
SEE
3
42
BELOW
4
602
5
6
P8
SWITCH FOR LOCAL OR REMOTE CONTROL
SHOWN IN LOCAL POSITION.
*
WITH MACHINE NOT RUNNING, REMOVE PLUG "P9" ON
MACHINE FROM CONNECTOR "J8". THEN CONNECT
PLUG "P8" ON REMOTE CONTROL TO
CONNECTOR "J8" ON MACHINE.
RED & BLACK LEADS NOT CONNECTED ON THIS
MACHINE.
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.
61
1 2 3 4 5 6 7 8 9 10
IDLER/ENGINE
J1
58
53B
PROTECTION
P.C. BOARD
CB1
57
62
53
56A
IDLER
60C
SOLENOID
56
IGNITION
SWITCH
IDLER
SWITCH
OIL TEMP.
P3
J3
SENSOR
51A
3
54B
4
54
OIL PRESSURE
53A
SENSOR
6
55
5
60A
7
S I
FUEL
GND
SOLENOID
GAUGE
8
OIL PRESSURE
59
9
ENGINE
60B
10
CONNECTOR
50
1
D+
W
60E
2
-
+
A
B+
51
ALTERNATOR
REMOTE CONTROL (OPTIONAL)
PLUG FOR
REMOTE CONTROL
POTENTIOMETER
G
X
RESISTORS
Y
R
G
W
CONNECT
TO CASE
REMOTE CONTROL
POTENTIOMETER BOX
ELECTRICAL DIAGRAMS
ELECTRICAL SYMBOLS
PER E1537
LEAD COLOR CODE
B-BLACK
R-RED
U-BLUE
G-GREEN
N-BROWN
W-WHITE
1
Y-YELLOW
2
3
J2
4
SLIP RINGS
R
115 VOLT
RECEPTACLE
G
G
CB1
G
(30AMP)
B
B
G
CURRENT
D-
W
TRANSFORMER
W
WIRE FEED MODULE (OPTIONAL)
Y
X
INLINE
CONNECTORS
W.F.M.
CONTROL
PANEL
W
B
CONNECT TO POS. & NEG.
OUTPUT TERMINALS
NEGATIVE CV
OUTPUT TERMINAL
PANEL
CONNECT TO NEG.
BRUSH HOLDER
R
CLEVELAND, OHIO U.S.A.
CONTROL PANEL COMPONENTS
SHOWN AS VIEWED FROM REAR.
P10
NEUTRAL BONDED TO FRAME
'
NEUTRE RACCORDE AU BATI
12
11
10
9
8
J5
W
B
ALTERNATOR
ROTOR
-
+
B
610
+
SLIP RING
610
NEAREST
R
TO IRON
AC
AC
600B
41
-
600A
230 VOLT
Y
RECEPTACLE
42
15A.
Y
FUSE
602A
RHEOSTAT
Y
B
R
ALTERNATOR
CB2
W
AUXILIARY
(15AMP)
POWER
WINDINGS
A
B
5 4 3
B
CR2 REED
WELDER
RELAY
LEAD BLOCK
R
N
NEGATIVE
POSITIVE
(CC- )
(CC+) & (CV+ WITH W.F.M.)
ON MACHINE, REMOVE PLUG "P10" FROM CONNECTOR "J5".
CONNECT PLUG "P5" ON W.F.M. TO CONNECTOR "J5" ON MACHINE.
PLUG
(P5)
#8 LEAD
WIRE
POS.
NEG.
MODULE
#2 HEAVY LEAD
608
609
#2 HEAVY LEAD
*
250 AMP
MACHINE MUST NOT BE RUNNING
THERMOSTAT
WHEN MAKING THESE CONNECTIONS.
ASSEMBLY
G-7
7
6
5
4
3
2
1
+Y
N
-W
U
602B
1
2
3
4
5
6
J8
P9
SELECTOR
SWITCH
GENERATOR
2 1
N
U
-W
+Y
FEED
1-19-96
L9919
CLASSIC II

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic ii

Table of Contents