9. ERROR CODE LIST

9-1. Error message
When an error occurs on the QT-2000 terminal, buzzer sounds and the error message
appears on the main LCD screen.
The following table lists the error messages and descibes the action to takae.
Prompt message
Operator mistake
E001 Wrong Mode
E003 Wrong operator
E005 Insufficient memory
E011 Close the drawer
E012 Change journal roll
E013 Change receipt roll
E016 Change back to REG mode
E017 Enter Check/TBL number
E018 Enter Table No.
E019 Enter Number of covers
E020 Enter Seat number
E023 Stock running short
E024 No stock is available
E027 Cancel buffer full.
Please finalize the transaction
E029 No registration is possible
while you are in the tender
operation.
E031 Press ST key before Finalization
E033 Enter tendered amount
E035 Change amount exceeds the limit.
E036 Remove money from the drawer.
E037 Digit or Amount Limitation Over
E038 Perform Money Declaration
E040 Issue Guest Receipt
E041 Print Validation
E042 Insert VLD Paper and retry
E043 Remove VLDed paper or check
VLD sensor
E044 Print Check
E045 Print Check-Endorsement
E046 REG Buffer Full. Please
Finalize or NB.
E047 Print bill
E048 Insert Slip Paper and retry.
E049 CHECK memory full
E050 Detail memory Full.
E051 CHK/TBL No. is occupied.
E052 CHK/TBL No. is busy.
Meaning
Operation error
Check tracking (Open mode error)
Error clerk/Error clerk in CHK tracking
Memory allocation over
Drawer compulsory
Journal paper near end
Receipt/order paper near end
Prohibit plural operation in RF mode
Check # compulsory
Table # compulsory
Cover compulsory
Seat number compulsory
Alarm when any item drops below its programmed mini-
mum stock quantity during registration
Error when actual stock value for a registration items is a
negative value
All void buffer full
Attemted registraion whilist partial tender operation is be-
ing done.
ST compulsory
Amount tender compulsory
Change amount exceeds the limit.
Contents of the drawer exceed the programmed limit—
Sentinel function
H.D.L., H.A.L.O error
Money declaration compulsory
Guest receipt compulsory
Validation compulsory
Alarm when no paper is inserted.
Alarm when the paper is left in the validation stage of the
printer.
CHK-PRT compulsory
CHK-END compulsory
Registration buffer full
Slip compulsory
Alarm when no paper is inserted in the Slip.
CHK tracking index full/near end
CHK tracking memory full/near end
Attempt made to use the New Check key to open a new
check using a number that is already used for and existing
check tracking memory
Attempt to use the same check number whilst the specified
number is used in the other terminal
— 67 —