(6) MCR test
Use only the checker magnet card.
Operation:
[n][0][7][SUB TOTAL]
n = Number of execution and should be within the range of 0 to 9.
If no number or "0" is input, the test continues endlessly.
To stop the test, press [ESC].
Display:
<LCD>
MCR
#1:OK #2:OK
#1:NG #2:NG
MCR#1
MCR#2
END
R/J Print:
MCR
#1:OK #2:OK
END
(7) Drawer test
Opens two drawers (multi drawer is optional) and shows open sensor status on the LCD.
Operation:
[n][0][9][SUB TOTAL]
n = Number of execution and should be within the range of 0 to 9.
If no number or "0" is input, the test continues endlessly.
To stop the test, press [ESC].
Display:
<LCD>
DRAWER
DRAWER:
END
R/J Print:
DRAWER
END
07
When the read data is incor-
rect, display indicates NG
and shows read data.
07
0
07
"NG" when incorrect
07
09
OPEN
"NOT OPEN" when drawer does
09
not open
0
09
09
— 52 —
<Dot/7-segment>
Dot/7-segment display indicates 0 only when
the test is continued from the "Dot/7-segment
display test." When the test is performed
indipendently, the dot/7-segment display indi-
cates nothing.
Note: When MCR read error occurs, the display in-
dicates "MCR READ ERR."
<Dot/7-segment>
Dot/7-segment display indicates 0 only when
the test is continued from the "Dot/7-segment
display test." When the test is performed
indipendently, the dot/7-segment display indi-
cates nothing.
0
0