(24) ARCNET test-3 (ARCNET communication stop)
Terminates the ARCNET communications.
Operation:
[4][0][SUB TOTAL]
Display:
<LCD>
R/J print:
ARC–STP
END
(25) ARCNET test-4 (ARCNET data transmission/reception)
Checks data transmission and reception in the ARCNET.
Preparation
Sender
Command code: 41
ARC–STP
40
OK
or "NG"
END
40
40
40
<Dot/7-segment>
0
Dot/7-segment display indicates 0 only when
the test is continued from the "Dot/7-segment
display test." When the test is performed
indipendently, the dot/7-segment display indi-
cates nothing.
ARCNET
Reciever
Command code: 42
— 65 —
0