REMEHA Gas 310 ECO Technical Information page 53

High efficiency condensing boiler with low nox emission
Hide thumbs Also See for Gas 310 ECO:
Table of Contents

Advertisement

16
APPENDICES
16.1 Control menu
fig. 40
Control menu flow chart
p df
62560.indd 53
62560.indd 53
step through modes with
in code- display
the m - key
Operating mode
0 - 9
b
only digit or letter
h
l
m
t
C L
Setting mode
!
s
@
digit or letter with dot
A
service engineer level only: servicecode
m
$
%
^
&
*
(
a
b
C
d
E
F
G
H
I
J
L
Read-out mode
!
s
@
digit or letter with flashing dot
#
%
m
^
&
*
(
A
b
C
D
E
F
G
H
1
Failure mode
s
2
digit flashes
3
4
m
5
6
7 + 8
9
a+b+c
d + e
1, ,, .
Counter mode
digit + , + .
s
2, ,, .
3, ,, .
4, ,, .
m
5, ,, .
6, ,, .
7, ,, .
1
Shut-off mode
s
2
flashing digit with flashing dot
3
4
m
5
6
7 + 8
9
a+b+c
d + e
in
- display
Flow temperature
Shut-off code
Forced full load (High)
Forced part load (Low)
Gas leakage control
Burner cooling
step within the mode with the s- key
Flow temperature setpoint
Pump run on time
Boiler control setting
c 12
Minimum fan speed (x 100)
Minimum fan speed (units)
Maximum fan speed (x 100)
Maximum fan speed (units)
Forced part load running time
Cycling prevention delay-time
Start point for 0 Volt analogue signal
End point for 10 Volt analogue signal
Switchpoint indication High/Low (x 100)
Run on time shunt pump
dT from control stop point to start point
Maximum flue gas temperature
High limit temperature setpoint
Modulation start point dT
Minimum water pressure
Adjustments options/accessories
"Low" fan speed (High/Low-control)
Actual flow temperature
Actual return temperature
Actual flue gas temperature
Actual heat exchanger temperature
Calculated flow temperature (setpoint)
Heat demand status and air pressure switch
Switch-on temperature for heating (Tflow)
Requested output (external control)
Calculated or actual output
Analog input voltage (V) - DC
Control strategy
Actual water pressure
not applicable
Actual fan speed
Actual ionisation level
Unique boilercode
Failure code
Operating mode, at failure
Flow temperature, at failure
Return temperature, at failure
Flue gas temperature, at failure
Time from failure (only with PC-software)
Heat exchanger temperature, at failure
Ionisation level, at failure
Operating hours burner, at failure
Fan speed resp. output, at failure
Number of operating hours burner
Number of successful ignition attempts
Total number of start attempts
Number of operating hours shunt pump
Total number of start shunt pump
Number internal resets (control unit)
Number of hours under tension (control unit)
Shut-off code
Operating mode, at shut-off
Flow temperature, at shut-off
Return temperature, at shut-off
Flue gas temperature, at shut-off
Time from shut-off (only with PC-software)
Heat exchanger temperature, at shut-off
Ionisation level, at shut-off
Operating hours burner, at shut-off
Fan speed resp. output, at shut-off
53