Burner and Injectors

Remove the two nuts fixing the burner manifold to the burner
feed pipe.
Remove the two nuts fixing the burner manifold to the
combustion chamber door.
Remove the two screws fixing the burner brackets to the
combustion chamber door.
Remove burner assembly, (noting position of pilot shield) 'O'
ring and gasket.
Check the 'O' ring and gasket, replace if necessary.
A replacement burner can be fitted by reassembling in
reverse order ensuring that the pilot shield is refitted in the
correct position.
If only the injectors are being replaced then proceed as
follows:
Remove the two screws fixing the mounting brackets.
Remove the four screws to separate the manifold from the
blade assembly.
Unscrew injectors and fit new ones.
Reassemble the burner and attach to controls door in
reverse order.

Gas Valve

The gas valve fitted to the appliance is of the stepped
ignition type.
Release fixing nuts on pilot feed pipe and thermocouple at
gas valve which releases the Eco interrupter.
Remove screws holding burner feed pipe to gas valve.
Remove the piezo igniter assembly.
Remove screws on gas valve inlet support bracket.
Remove gas valve. Undo Eco interrupter from rear of valve.
Fit new gas valve and reassemble using the "O" ring from
the original valve. If however the "O" ring has become
damaged or worn, replace.
39