Baxi Solo 2 60 RS Installation And Servicing Instructions page 21

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

Installation - Page 21
Water Connections
The boiler is supplied ready for fully pumped and sealed
systems.
The boiler has 2 connection tails to accept capillary or
compression fittings:-
22mm tail marked F for Flow.
22mm tail marked R for Return.
Pipe Routes
Pipework should be routed to the back plate. Pipes may also
be routed to drop down within outer case. Spaces are
available at both sides. If pipes are routed to drop down
within the outercase vents are required.
It is recommended that fittings 'A' are of copper capillary
type.
It is recommended that fittings 'B' are compression type.
Fully Pumped System
For fully pumped system, connect to tails marked F and R.
Sealed System
For sealed system, connect to tails marked F and R.