Baxi Solo 2 60 RS Installation And Servicing Instructions page 24

Wall mounted room sealed gas fired central heating boilers
Table of Contents

Advertisement

Installation - Page 24
Loosen the securing screw sufficiently for the electrical cover
to be removed from the thermostat box.
Bare back the input cable to the dimensions shown.
Fit the electrical input cable as follows:
Connect the switched live to the terminal marked S/L.
Connect the permanent live to the terminal marked P/L.
Connect the supply neutral to the terminal marked N and the
supply earth to the terminal marked
Secure the cable in place with the right hand cable clamp.
Fit the pump outlet as follows:
Connect the pump earth to the terminal marked
.
Connect the pump neutral to the terminal marked N.
Connect the pump live to the terminal marked L.
Secure the cable in place with the left hand cable clamp.
Replace the electrical cover and securing screw.
A cable clip is supplied in the kit to secure the cable to the
bottom of the combustion box.
In the event of an electrical fault after installation of the
appliance, preliminary electrical system checks should be
carried out:- earth continuity, polarity and resistance to earth.
24