Cleaning The Burner / Injectors - Baxi Bermuda SP3 Installation And Servicing Manual

Hide thumbs Also See for Bermuda SP3:
Table of Contents

Advertisement

Supplied By www.heating spares.co Tel. 0161 620 6677

Cleaning the Burner / Injectors

Remove the burner as follows:
Remove the locating pins (these also
secure the burner to its support brackets).
Disconnect the compression nuts from the
injectors. Remove the burner from the fire.
Using a soft brush remove any dirt or debris
from the top of the burner and ensure that the
ports and aeration openings are free from
obstruction.
Release and remove the injectors from the burner.
Examine and clean carefully then replace.
BEFORE RE-ASSEMBLING ALL COMPONENTS
Examine the glass frame, if the glass is in any way
damaged, then it must be replaced.
NOTE: This is a heat resistant glass and must not
be replaced by "ordinary" glass.
The glass may be cleaned with a non-abrasive
cream cleansing agent if required.
Examine the glass frame sealing rope on the
fire and replace it if in any way damaged.
Examine the coal bed and replace it if any
major damage has occurred.
Re-assemble all components in reverse
order, ensuring that the flue spigot is
engaged into the boiler down-draught
diverter. Make good all gas and electrical
connections and check for gas soundness.
Recommission the fire and boiler before use,
then re-assemble the outercase components in
the reverse order of dismantling.