Site Requirements - Page 14
Ventilation of Compartments
Where the appliance is installed in a cupboard or
compartment, air vents are required (for cooling purposes) in
the cupboard or compartment at high and low level which
may communicate with a room or direct to outside air.
Detailed recommendations for air supply are given in BS
5440: Part 2.
An existing cupboard or compartment may be used,
provided that it is modified for the purpose.
Recommendations for air supplies and details of essential
cupboard compartment design are given in BS 5440: Part 2.
NOTE: Both air vents must communicate with the same
room or both be on the same wall to outside air.
Gas Supply
The gas installation should be in accordance with BS 6891.
The connection on the appliance is RC½ (½ in BSPT
internal) located at the bottom right hand side of the
appliance.
Ensure that the pipework from the meter to the appliance is
of adequate size. Do not use pipes of a smaller diameter
than the appliance gas connection.
Electrical Supply
External wiring must be correctly earthed, polarized and in
accordance with CURRENT I.E.E. WIRING REGULATIONS.
The mains supply is 230V ~ 50Hz fused at 3A. NOTE: The
method of connection to the electricity supply must facilitate
complete electrical isolation of the appliance, preferably by
the use of a fused three pin plug and unswitched shuttered
socket outlet, both complying with the requirements of BS
1363.
Alternatively, connection may be made via a fused double-
pole isolator with a contact separation of a least 3mm in all
poles and serving the appliance and system controls only.
14