Ecdis Control Unit Rcu-024; Control Description - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

1.5

ECDIS Control Unit RCU-024

The RCU-024 consists of controls, keys, alphabet keyboard and trackball module
(trackball, scrollwheel and left and right mouse buttons). The trackball module func-
tions like a PC mouse. The operator rolls the trackball and operates the left and right
mouse buttons and the scrollwheel to do various functions.
Rotary encoder
for EBL
InstantAccess
knob
1.5.1

Control description

POWER switch
Status LED
EBL rotary encoder
EBL 1
Keyboard
Key
Turns the system on or off. (With a FURUNO monitor unit,
the monitor is also turned on or off with this switch.)
The color and state of the LED change according to system
or alert status.
Green, lighting: Normal operation status; no alerts gener-
ated.
Green, flashing: The heater on the CPU board is on, be-
cause ambient temperature is not at least 0°C. The heater
takes about two minutes to warm the equipment. The LED
lights green after the heater goes off.
Red, lighting: Acknowledged alert or SYSTEM FAIL. SYS-
TEM FAIL occurs when there is trouble in the Processor
Unit or communication failure between the Processor Unit
and an ECDIS Control Unit. Each Control Unit detects trou-
ble and its lamp flashes in red and the buzzer sounds. If
this condition occurs at the No. 1 ECDIS Control Unit, the
SYSTEM FAIL signal is output.
Red, flashing: Unacknowledged alert or SYSTEM FAIL.
Adjusts active EBL.
Activates or deactivates EBL 1.
Status LED
Rotary encoder
for VRM
Description
1. INTRODUCTION
USB port
POWER switch
Trackball module