General information

This folder contains instructions on how to assem-
ble and install stoves in the Contura 500 series. The
stove also comes with comprehensive Lighting and
Maintenance Instructions. Please take time to read
all this information carefully and keep it in a safe
place for future reference.
Contura 500 series stoves have been type-approved
in Sweden for connection to a chimney which can
withstand flue gas temperatures of 350 °C. The con-
necting sleeve has an external diameter of 150 mm.
To ensure proper combustion, sufficient air must be
supplied to the stove from outdoors.

Technical specifications

Output
4 – 7 kW
Nominal output
5 kW (ca. 1,5 kg logs/hr)
Efficiency, up to
80%
Connecting ext.
Ø150 mm
510
520T
Weight (kg)
100
210
Width (mm)
500
564
Depth (mm)
440
470
Height (mm)
1010
1032
560K
570
Weight (kg)
115
100
Width (mm)
540
500
Depth (mm)
460
440
Height (mm)
1010
1010
Type approved in accordance with:
European standard EN-13240 class 1
Swedish environmental and quality certification,
"P marked" cert. no. 22 03 09
Swedish type approval, cert. no. 0222/03
Norwegian standard NS 3059, certificate no. 043-140
German standard DIN 18.891, RO-91 03 529
Danish standard DS/EN 13240 plus, id nr 598
DEFRA exempted.
 T he stove can be used in Smoke Control Areas.
Smouldering, i.e. reduced air supply, are prevented
byblockingthecombustiondamperof4kWoutput.
Building permission
It may be necessary for you to apply for building
permission from your local planning authority before
installing a stove or erecting a chimney. Before
start ing installation work, make sure that you check
which regulations apply.
550
560T
100
145
500
540
440
460
1010
1010
580
585
100
100
496
496
(base Ø510)
(base Ø510)
440
440
(base Ø510)
(base Ø510)
1040
1156
Grate disc
Rostertallrik
Ash-pan
Asklåda
Heat reflector
Strålningsplåt
Structural support
Check to make sure that the floor is strong enough
to support the weight of the stove and chimney. If
you intend to locate the stove on standard wooden
floor joists, contact a professional builder to make
sure that the construction will withstand the load. If
the total weight does not exceed 400 kilos, it is not
usually necessary to reinforce the joists.
Floor plate
To protect the floor from sparks and falling embers
the stove must stand on a non-combustible surface
which extends at least 300 mm in front of the stove
and 100 mm along each side. As other statutory
requirements apply in some countries, we recom-
mend that you consult the relevant authority or an
authorised chimney-sweep in your area.
Chimney
The draught in the chimney must generate a neg ative
pressure of at least 12 Pa. The draught is affected
both by the length and cross-sectional area of the
chimney, and by how well sealed the construction
is. The shortest recommended chimney length is
3.5 metres. The cross-sectional area of the chimney
must be approximately 150–200 cm² (140–160 mm
in diameter).
Make sure that there are no gaps around soot hatch-
e s and flue-pipe connections.
Remember that the draught is reduced in flues with
sharp bends or horizontal sections. A horizontal flue
length of up to 1.0 metre is permissible, provided
that the vertical flue is at least 5.0 metres in height.
It must be possible to clean the flue throughout its
entire length, and the soot hatches must be easily
accessible.