Doss WDA-KIT ALARMFONE User Manual
Doss WDA-KIT ALARMFONE User Manual

Doss WDA-KIT ALARMFONE User Manual

Wireless security system for home and small business

Advertisement

Quick Links

WDA-KIT ALARMFONE USER MANUAL
Wireless Security System for Home and Small Business
Thank you for purchasing this product.
For optimum results and safety, please read these instructions carefully.
Before installing, operating or adjusting this product, please read these
instructions completely. Please keep this manual for future reference.
IMPORTANT - PLEASE READ VERY CAREFULLY BEFORE SET UP
1.
Alarm Security and Insurance
Any alarm system is not a substitute for adequate insurance cover.
Please review your insurance needs and ensure adequate insurance for
your property, goods and persons.
2.
Access To Your Property
Unwanted persons may enter your property via points of access which
are not protected by sensors or by disconnecting a sensor device.Please
ensure all locks on all doors and windows operate securely and additional
sensors are used to cover all access points.An evaluation of your security
needs by a security expert is recommended.
3.
Batteries
This alarm system's wireless transmitters batteries and Main Unit phone
back-up batteries (not supplied) should be high quality heavy-duty (alk-
aline or lithium) batteries - AAA (1.5V) for the wireless PIR Monitor
Detectors and AA (1.5V) for the Main Unit phone. The expected life of
the batteries is a function of the use environment. All batteries should
be replaced at least annually.
While the PIR Motion Detectors have a low battery monitor when these
batteries require replacement, the monitor may fail to operate.
Always use heavy-duty (alkaline or lithium) batteries -do not use
rechargeable batteries.
4.
Components
This alarm system is extremely reliable and subject to vigorous quality
control. However, due to the large number of components, the system
may fail to function due to the failure of a single component.
5.
Criminal Intent
It is feasible for technologically-orientated persons of criminal intent to
develop techniques to reduce the effectiveness of any alarm security
system. It is therefore critical to periodically review your security needs
and the protection provided by this alarm system and to replace or

Advertisement

Table of Contents
loading

Summary of Contents for Doss WDA-KIT ALARMFONE

  • Page 1 WDA-KIT ALARMFONE USER MANUAL IMPORTANT - PLEASE READ VERY CAREFULLY BEFORE SET UP Alarm Security and Insurance Wireless Security System for Home and Small Business Any alarm system is not a substitute for adequate insurance cover. Please review your insurance needs and ensure adequate insurance for your property, goods and persons.
  • Page 2 Update the system if it does not provide the necessary protection that Power Failure you require. Power failure or interruption resulting in voltage fluctuations can damage electronic systems. After any power fluctuation immediately conduct a Insufficient Response system test to ensure the system is fully operational. Refer to the 'User Responsiveness by third parties is outside the control of the alarm Guide' index for testing instructions.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS FEATURES The Doss Alarmfone is a complete home protection and security FEATURES....................Page 1 Pack Contents....................Page 1 system using the latest technology of wireless sensors. With no messy Equipment Summary..................Page 2 wiring, installation is quick and easy by simply replacing your existing QUICK SETUP GUIDE..................
  • Page 4: Equipment Summary

    Door Gap Sensor The Door Gap Sensor is a surface mounted magnet and reed switch. The Door Gap Reed Switch is mounted on the door frame and the magnet parallel on the edge of 2 x Remote Control Medical Alert Pendant 8 x Screws the door so the two parts sit neatly together when the door is closed.
  • Page 5: Quick Setup Guide

    QUICK SETUP GUIDE Main Unit Setup INTERNAL SIREN EXTERNAL SIREN DV 12V 500mA LCD Display 02:30 29 05 DISARM PIR LOW POWER DISARM INDICATOR ARM/DIS HOLD TIME VOLUME LEVEL PARTIAL SAVE REDIAL ALARM INDICATOR DIGIT DISPLAY AREA MODE SPEAKER DATE ALPHABET DISPLAY AREA SETUP DOWN...
  • Page 6 Step 1: Step 4: Install six "AA" type batteries into the Main Unit ensuring the poles (+ and -) Plug the power supply adapter into a power point and the adaptor's output match those of the Main Unit. pin into the socket on the back of the unit. EXTERNAL LINE DO NOT...
  • Page 7: Door Gap Sensor Setup

    Door Gap Sensor Setup Passive Infrared Sensor (PIR) Setup Step 1: Step 1: Unpack the Door Gap Sensor Reed Switch and its Magnet and open the Unpack the wireless PIR Sensor and open the battery compartment door on battery compartment on the side. the side.
  • Page 8: Quick Tabletop Test

    Quick Tabletop Test Step 3: Before installing, it is highly recommended that you carry out a quick test to Arm the Main Unit by pressing "ARM" button on the Remote Control. The familiarise yourself with the equipment and ensure everything is operating Main Unit LCD screen will change its status to "ARM".
  • Page 9: Installation Guide

    Step 14: Disconnect the phone line. The Main Unit will start beeping. Reconnect the If you have a cordless phone in addition to the Doss Alarmfone, phone cable and the beeping will stop. simply connect that phone's cable to the jack marked "EXT" on the Step 15: back of the Main Unit.
  • Page 10: Door Gap Sensor Installation

    Door Gap Sensor Installation Step 3: Step 1: Install Magnet on door using two of the provided screws. Identify the best location on the door and door frame for the Door Gap Sensor and Magnet to be installed parallel to each other. The distance between the parts should not be more than 1.5cm and they must sit flash as shown in the diagram.
  • Page 11: Pir Sensor Installation

    PIR Sensor Installation Step 3: Install the bracket to the wall or ceiling with the 2 screws provided. Step 1: Please refer to the "Quick Setup Guide" section. Step 2: The best location for the PIR is in the corner of the room that will allow the PIR to monitor the maximum area.
  • Page 12: Avoiding False Alarms

    Note: It is recommended that you read carefully the last section "Zones" and draw a rough floor plan of your property marking all intended protected zones and the location of each sensor before installing you Doss Alarmfone. Avoiding False Alarms ¡...
  • Page 13: Operation Guide

    12:30 10 04 DISARM 345678 M1 :Jo_ Call number display: The Doss Alarmfone will automatically display the incoming call Repeat for M2, M3, M4, M5, M6 number on the LCD screen. Step 6: Press "*" key to exit the menu.
  • Page 14: Brightness

    Brightness Time and Date Setting The Doss Alarmfone has a built-in electronic clock and You can adjust the brightness of the LCD screen as required. 1 PHONE BOOK calendar. 1 PHONE BOOK 2 BRIGHTNESS SET DATE 2 BRIGHTNESS 3 TIME/DATE...
  • Page 15: Incoming Calls

    Incoming Calls Outgoing Calls Select this option to display a list of the last ten caller numbers and the time Select this option to display the list of the ten most recently dialled numbers of call. and the time of the call. 1 PHONE BOOK 1 PHONE BOOK 2 BRIGHTNESS...
  • Page 16: Alarm Settings

    ALARM SETTINGS Change Password Note: You must change the default password (1234) when you up your Doss Alarmfone for the first time. Step 1: set- Press the "#" key to select CHANGE PSW option. To set up your alarm function press the "SETUP" button on your Main Unit without lifting the handset.
  • Page 17: Base Numbers

    Step 3: Base numbers are the phone numbers for the security Monitoring The LCD screen will display STATION 1. Press the "#" key to select. Station that will pick up the alerts sent by your Doss Alarmfone. This 12:30 10 04 option also allows you to set up self monitoring of your security system.
  • Page 18 This option is used when you choose not to have your alarm monitored The LCD will display PLS INPUT CID. Enter the four digit account number by a security monitoring service. In this case your Doss Alarmfone supplied by your Monitoring Station and press the "SAVE" button.
  • Page 19: Deleting Base Numbers

    Deleting Base Numbers Step 3: Select this option to delete either of the previously set up Monitoring Station The LCD screen will display TEL 1. Press "#" key to select the option. numbers. 12:30 10 04 DISARM Press the "SETUP" button. After entering your four digit password press the T EL 1 "DOWN"...
  • Page 20: Deleting Self Monitoring Numbers

    Deleting Self Monitoring Numbers Step 5: Press "DEL" button to delete Station 2 number. The LCD screen will display Use this option when you want to delete any of the numbers in the self ACCOUNT. monitoring menu. 12:30 10 04 DISARM 0002 ACCOUNT...
  • Page 21: Delay Time

    Delay Time Step 5: The delay time option is used for key pad arming when you are not using Press the "DEL" button to delete the second number. your Remote Control. Delay time is the time you need to leave your premises. Repeat these steps for deleting "TEL 3-TEL 9"...
  • Page 22 PIR Low Power This option allows to identify which zones are running low on batteries. REGISTER NEW PARTIAL CLEAR ZONE Press the "SETUP" button and enter your four digit password. Press the BASE NO. DEL BASE NO. "DOWN" button nine times and the LCD screen will display PIR LOW POWER. DELAY TIME SIREN TIME 1 REGISTER NEW...
  • Page 23: Partial Alarm Function

    Partial Alarm Function Step 4: Also known as "bypass", this function is designed for higher security so you Change the zone status to partial ON or OFF by press the "UP/DOWN" can keep some zones armed while you are at home. For example, if you sleep buttons.
  • Page 24: Siren Time

    Status to Base Siren Time This option allows you to choose the siren duration when your alarm is trigg- This option enables the Monitoring Station to know each time you arm or ered. The available options are 3, 5, or 10 minutes. disarm your security system.
  • Page 25: Clear Zone

    Clear Zone This option allows you to clear or delete PIR Sensors or Door Gap Sensors from a particular zone. It is necessary to do this if; 1. You want to reduce the number of PIR Sensors/Door Gap Sensors in a specific zone.
  • Page 26: Arming And Disarming

    ARMING AND DISARMING Step 3: The Doss Alarmfone can be armed and disarmed via Remote Control The LCD screen will display the zone status. To change the status to NO or or directly from the telephone key pad. You can also arm and disarm YES options, press the "UP/DOWN"...
  • Page 27 Press "1" for this function. Step 4: To log out simply hang up. Arming and Disarming from A Remote Location: To arm and disarm your Doss Alarmfone from a remote location, call the Doss Alarmfone number. 00:00 00 00...
  • Page 28: Alarm Types

    PIR while the security system armed. monitors all its customer's security systems. When an alarm is triggered, the Doss Alarmfone sends the alert to the Monitoring Intruder alarm: Station via the telephone line. When the alert is received, the...
  • Page 29: Self Monitoring

    The self monitoring function works in the same way as Back to Base Additional devices need to be registered (or logged in "login") with the Main Monitor-ing except that the Doss Alarmfone sends the alert directly to Unit. Unless a new device is correctly registered it will not operate as part of you via the telephone line.
  • Page 30 Step 4: Press the "#" key to select the option. The LCD scree will display PLS TRIGGER PIR. Step 5: To 'trigger' the PIR, place the batteries in the PIR and then open and close the PIR battery compartment. The LCD screen will display TRIGGER AGAIN. Step 6: Open and close the PIR battery compartment again.
  • Page 31 Step 5: To 'trigger' the Door Gap Sensor, insert the battery and put the magnet and sensor together and then separate them. The LCD screen will display TRIGGER AGAIN. Step65: Put the magnet and sensor together again and then separate them. The LCD screen will display SUCCESS LOGIN.
  • Page 32 REGISTER NEW PARTIAL CLEAR ZONE ZONE 0 PLS TRIGGER R.M STEP 2 STEP 1 BASE NO . TRIGGER AGAIN STEP 3 LOGIN PIR DEL BASE NO . SUCCESS LOGIN STEP 4 LOGIN DOOR DELAY TIME LOGIN REMOTE SIREN TIME LGN EMERGENCY STATUS TO BASE LOGIN GAS CHANGE PSW...
  • Page 33 Step 5: Press the "SETUP" button and enter your four digit password. Press the Press any button on the pendant again. The LCD screen will display SUCCESS "DOWN" button until the LCD screen displays REGISTER NEW. LOGIN. 12:30 10 04 DISARM REGI STER N EW Step 1:...
  • Page 34 New Smoke Detector Press the "SETUP" button and enter your four digit password. Press the "DOWN" button until the LCD screen displays REGISTER NEW. Step 1: Press the"#" key to select the option. LOGIN PIR LOGIN DOOR LOGIN REMOTE LGN EMERGENCY REGISTER NEW PARTIAL LOGIN GAS...
  • Page 35: Maintenance/Service

    MAINTENANCE/SERVICE Step 5: epeat the smoke detector trigger process again. The LCD screen will display The Doss Alarmfone is a complete home protection and security SUCCESS LOGIN. system using the latest technology requiring a minimum level of maintenan- ce. However, regular testing can identify potential problems of system failure.
  • Page 36: Zones

    ZONE NO. Area Device Smoke Detector ZONE 10 triggered at your premises. Ground Level & First Floor The Doss Alarmfone security system has 10 zones. Maximum No. Zone No. Assigned to of Devices Remote Controls ZONE 2 (PIR) ZONE 7 (DG)

Table of Contents