2.5 Winterizing
Winterizing is essential due to the risk of the condenser freezing. This situation is
not covered by the warranty.
switch off the heat pump by pressing the
the power cable,
ensure that no water is flowing through the heat pump,
drain the water condenser (risk of freezing) by removing the two pool water inlet and
outlet connections at the back of the heat pump,
in the case of a full winterizing of the pool: connect the inlet and outlet connections
"lightly" without tightening (one turn) in order to avoid foreign bodies entering into
the condenser,
in the case of winterizing the heat pump alone: do not reconnect the inlet and outlet
connectors, instead place two stops (supplied) on the condenser water inlet and
outlet.
To avoid damaging the appliance with condensation, do not cover it with an air‐
tight cover.
Maintenance
3.1 Maintenance instructions
A general servicing of the appliance is recommended both when winterizing and
when restarting in order to ensure the proper operation of your heat pump, to
preserve its performance and to prevent potential failures.
Servicing costs will be borne by the user.
Do not use a high‐pressure water hose.
ensure that no foreign bodies obstruct the fan grid,
clean the inside of the appliance, do not use solvent‐based cleaning products,
clean the evaporator (for placing see§ "Dimensions" in appendix) with a soft brush
and a fresh water hose (disconnect the power cable), do not twist or bend the metal
blades,
check the correct operation of the regulator,
check that the condensation is drained properly whilst the appliance is operating.
The following operations must be performed by a qualified technician:
check the correct working condition of all safety components,
check that all metal elements are earthed,
check the tightening and connections of the electric cables and the cleanliness of the
electrical equipment box,