It is possible to fix the appliance to the ground using the holes in the base of the
appliance or using fixing rails (not supplied). It is also possible to fix the appliance
with brackets (not supplied).
A drilling explanation diagram is available on the rear of the packaging box.
1.3.3 Hydraulic connections
Respect the direction of the hydraulic connection (see § "Dimensions" in the
appendix).
Connections should be made using Ø50 PVC pipe, gluing the pipework connectors to
the swimming pool filtration system, after the filter and before any water treatment
system . In order to ensure the water tightness between these joints and the heat
pump, wrap Teflon tape around the threading of the water intake and output.
Even if the water flow is lower than 8m³/h, it is recommended that a by‐pass
installation be used (valve VB closed, valves VE and VS open) so as to facilitate
interventions on the appliance.
H03579‐03.A1.SA
With by‐pass
(recommended)
Without by‐pass
Ver. 11/2011
* Minimum distance
filter
water treatment
by‐pass
4