14-3 CAMERALINK INTERFACE SPECIFICATIONS
14-3-1 CAMERALINK INTERFACE
CameraLink interface is a standard of a standard digital interface for industrial application
standardized by digital camera manufactures and frame grabber board manufactures. 28 bits
digital data (TX0 to TX27) can be transferred as being changed into 5 signals (X0, X1, X2, X3,
XCLK) by parallel serial transformation. This camera is based on CameraLink interface and Base
Configuration 12 bit digital camera standard.
(1) CameraLink connector pin assignment (MDR-26)
Camera connector
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Note
Frame grabber connector
1
25
24
23
22
21
20
19
18
17
16
15
13
14
12
11
10
9
8
7
6
5
4
3
2
26
•
CC1 to CC4 are options. It is possible to use an external trigger.
So when it is needed, please feel free to contact Hamamatsu
subsidiary or local distributor.
HAMAMATSU PHOTONICS K.K.
C9300-201 Ver.1.2
Channel Link signal
Inner Shield
X0-
X1-
X2-
Xclk-
X3-
SerTC+
SerTFG-
CC1-
CC2+
CC3-
CC4+
Inner Shield
Inner Shield
X0+
X1+
X2+
Xclk+
X3+
SerTC-
SerTFG+
CC1+
CC2-
CC3+
CC4-
Inner Shield