How To Provide Remote Access; How To Disable Remote Access; How To Call To Avoice Mail Or Extension Number; How To Use The 4-Digit Access Code To Unlock The Door - PACH & COMPANY AeGIS 7000 Series Installation And Programming Manual

Hide thumbs Also See for AeGIS 7000 Series:
Table of Contents

Advertisement

HOW TO PROVIDE
REMOTE ACCESS
HOW TO DISABLE
REMOTE ACCESS
HOW TO CALL TO A
VOICE MAIL OR
EXTENSION NUMBER
HOW TO USE THE 4-
DIGIT ACCESS CODE
TO UNLOCK THE
DOOR.
HOW TO ADJUST THE
SPEAKER AND
MICROPHONE VOLUME
HOW TO ADJUST THE
LCD DISPLAY
HOW TO ADJUST THE
PULSE SENSITIVITY
HOW TO CHECK THE
NUMBER OF THE
TENANTS
PROGRAMMED IN THE
SYSTEM.
Pach and Company
AeGIS 7000 Series
Press 9 to unlock the door.
Function Code 77 is to disable remote access. Disabling remote access means disable
number 9 from unlocking the door.
Press the voice mail or extension number after the call is connected.
The personal Access Code is used to unlock the door without using the key. It is not
mandatory for the manager to provide a personal access code for each tenant. If you
decide not to provide a personal access code to each tenants, all you have to do is to
leave the Access Code Field blank when you program the tenant directory. See
Function code 01.
Step 1 Press
and the screen stops scrolling then press the 4-digit access code.
*
The speaker volume and microphone are factory preset. The adjustment pot is VR2, see
figure 2.1. Turn the speaker volume adjustment pot counter-clockwise to increase or
clockwise to decrease the speaker volume. If you hear a "feedback" when you closed
the panel door, decrease the speaker and microphone volume.
Turn the LCD Adjustment Pot ( VR3) clockwise to increase or counter-clockwise to
decrease the intensity. See figure 2.1 to locate the LCD adjustment pot.
The Pulse sensitivity is factory preset. An adjustment is necessary if the system is in a
dial tone mode (press # to get a dial tone) and the PULSE SENSITIVITY LED1 flashes
or ON (see figure 2.1). If the PULSE SENSITIVITY IS TOO SENSITIVE, the system may
unlock the door by itself without pressing 9. Follow the instruction below to adjust the
pulse sensitivity:
Step 1 Apply power to the system and connect the phone line.
Step 2 If the Pulse Sensitivity LED1 flashes or ON when the system is in dial tone
mode (press #), decrease the pulse sensitivity by turning the Pot adjustment
(VR1) clockwise, otherwise proceed to step 3.
Step 3 If the Pulse Sensitivity LED1 does not flash or ON, press the keypad number
0-9 and the LED should be flashed every time the key number is pressed. If it
does not flash, increase the sensitivity by turning the pot counter-clockwise.
You cannot program the tenant's directory more than the system capacity. An accurate
tenant's record is essential. You must delete any unused tenant's directory to free the
system's memory. If you program a tenant database without programming the
tenant's name, the system will not record it in the memory and you will not get an
accurate number of tenant in the memory. You may check the total number of
tenant in the system as follow:
Step 1 Log on to programming mode (see section 3.1), the display shows:
Step 2 Press * to exit, then the display shows:
XXX is the total number of tenant in the system.