PACH & COMPANY AeGIS 8000 Series Installation And Programming Manual

Telephone access control systems
Hide thumbs Also See for AeGIS 8000 Series:

Advertisement

AeGIS 8000 Series
Installation and Programming Manual
REV. 7.0
PACH & COMPANY
941 Calle Negocio
Phone: 1-888-678-7224
www.pach-co.com
San Clemente, CA 92673
Fax: 949-498-6879

Advertisement

Table of Contents
loading

Summary of Contents for PACH & COMPANY AeGIS 8000 Series

  • Page 1 AeGIS 8000 Series Installation and Programming Manual REV. 7.0 PACH & COMPANY 941 Calle Negocio Phone: 1-888-678-7224 www.pach-co.com San Clemente, CA 92673 Fax: 949-498-6879...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Chapter 1. Getting Started ------------------------------------------------------------ 1 1.1 Introduction --------------------------------------------------------------------------- 1 1.2 System Description, specifications and accessories ---------------------- 1 1.3 Unpacking the system ------------------------------------------------------------- 2 1.4 Warranty ------------------------------------------------------------------------------ 3 Chapter 2. Installation ------------------------------------------------------------------ 4 Chapter 3. Programming -------------------------------------------------------------- 7 Programming Function Code (table 3.1) ------------------------------------------ 7 * ---------------------------------------------------------------------------------------------- 7 # --------------------------------------------------------------------------------------------- 7...
  • Page 4 Pach and Company does not assume any liability for any damages, which may arise in installation or use of the AeGIS 8000 Series. Pach and Company does not assume liability for any incompatibility between the AeGIS 8000 Series and users devices.
  • Page 5: Chapter 1. Getting Started

    A mounting ring is required for full-flush mount. The manual is designed to guide you through the proper programming and use of the AeGIS 8000 Series. It is important for you to read and follow the manual completely. THE INSTALLATION AND PROGRAMMING MANUAL AND SOFTWARE PROGRAMMING MANUAL ARE ALSO AVAILABLE IN THE CD ROM The Aegis 8000 Series comes with two years warranty, see section 1.4 for detail.
  • Page 6: 1.3 Unpacking The System

    If they do not match, please contact Pach and Company toll free number at (888) 678-7224. All the items listed below come with the AeGIS 8000 Series. Some of the parts may not be listed below. If you have missing items, please contact your distributor or Pach and Company at (888) 678-7224.
  • Page 7: Warranty

    10. Pach and Company is not responsible for time, travel, and/or labor costs of any distributor and/or dealer-installer, including but not limited to, any expenses to install, uninstall or reinstall hardware/software/firmware related to warranty issues, product enhancements, or product failures. Pach and Company Chapter 1 Page 3 AeGIS 8000 Series GETTING STARTED...
  • Page 8 NEW PRODUCT WARRANTY EXCEPTION WIEGAND CARD, KEYFOB AND TRANSMITTER Pach and Company warrants the wiegand card, clam, and keyfob to be free of defects in material or workmanship for a period of three (3) months from the date of invoice. The above warranty is subject to the following conditions. 1.
  • Page 9 3. Warranty is immediately null and void if the product has been altered, repaired, or modified without express written authorization from Pach and Company Technical Department, with such authorization given only to manufac- turer approved dealer/installers. 4. Under no circumstances will Pach and Company honor warranty any product found to have been altered, repaired, and/or modified by the end-user consumer.
  • Page 10 shipped to Pach and Company repair center. 9. Pach and Company warranty does not guarantee any product, new or repaired, to be free of operation error or service interruption in any way during the course of daily product operation 10. Pach and Company is not responsible for time, travel, and/or labor costs of any distributor and/or dealer-installer, including but not limited to, any expenses to install, uninstall or reinstall hardware/software/firmware related to warranty issues, product enhancements, or product failures.
  • Page 11: Chapter 2. Installation

    A proper installation of the AeGIS system is very essential. You MUST follow the installation procedures, block diagrams and installation requirements as specified in this chapter. Heater Pad Thermostat Figure 2.1 Pach and Company Chapter 2 Page 4 AeGIS 8000 Series INSTALLATION...
  • Page 12 Use separate power supply for the isolation relay. POSTAL LOCK The AeGIS 8000 Series comes with pre-wired "Normally Open" postal switch as shown on figure 2.2(a). If the postal switch is pressed, the gate will open. If you need "Normally Closed" postal switch, see figure 2.2(b).
  • Page 13 A 12 VAC 40VA transformer is supplied by Pach and Company. However, 12 VDC 40VA power supply can be used to power the AeGIS 8000 Series use the same connection as shown on figure 2.1. The DC output must be between 13.5 VDC-14.0 VDC, if the output is less than the range specified, the relay will not work and the door will not function properly.
  • Page 14: Chapter 3. Programming

    Chapter 3 PROGRAMMING The AeGIS 8000 Series can be programmed LOCAL via built-in keypad or REMOTE via modem (see Management Software Manual for remote programming). LOG ON TO PROGRAMMING MODE Two ways to log on to programming mode: Using a valid master code Step 1: PRESS 0 AND # SIMULTANEOUSLY THEN RELEASE, the display screen will stop scrolling.
  • Page 15: Add A New Tenant

    * to clear all letters or numbers entered or to reset • Press the keypad’s letters if the letters are out of sequence. For example: to enter PACH 12 • Press 7 once for letter P then press # Pach and Company Chapter 3 Page 8 AeGIS 8000 Series PROGRAMMING...
  • Page 16: Edit An Existing Tenant

    Step 5 • To change the phone number press * and program a new one the press #. • To keep the phone number press # The display will show Pach and Company Chapter 3 Page 9 AeGIS 8000 Series PROGRAMMING...
  • Page 17: Delete An Existing Tenant

    Step 5 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 10 AeGIS 8000 Series PROGRAMMING...
  • Page 18: Manual Unlock And Lock Relay 1

    Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 11 AeGIS 8000 Series PROGRAMMING...
  • Page 19: System Id Number

    Step 6 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 12 AeGIS 8000 Series PROGRAMMING...
  • Page 20: Open Relay 1 (Door 1) Time Interval

    • 1 to enable daylight saving (most region, except Arizona and Hawaii) then press # • 0 to disable daylight saving (Arizona, Hawaii and some parts of Indiana) then press # Pach and Company Chapter 3 Page 13 AeGIS 8000 Series PROGRAMMING...
  • Page 21: Verify The Current Time

    Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 14 AeGIS 8000 Series PROGRAMMING...
  • Page 22: Relay 1 (Door 1) Remote Access Number Selection

    Step 1 Log on to programming mode, see instruction above. The display will show VERIFY MODEL AND FIRMWARE VERSION Select Func: _ _ Step 2 Enter function code 46 then press #, the display will show V :XXXXA MM/DD/YY Pach and Company Chapter 3 Page 15 AeGIS 8000 Series PROGRAMMING...
  • Page 23: Clear The Memory To Factory Default

    ENABLE OR DISABLE MODEM (Default setting is 1 for enable) Select Func: _ _ Step 2 Enter function code 71 then press #, the display will show EN-MODEM (0,1) : 1 Pach and Company Chapter 3 Page 16 AeGIS 8000 Series PROGRAMMING...
  • Page 24: Lock-Out Count

    Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 17 AeGIS 8000 Series PROGRAMMING...
  • Page 25: Enable Or Disable Keypad Press Beep

    Step 5 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear “ three short beeps”. Pach and Company Chapter 3 Page 18 AeGIS 8000 Series PROGRAMMING...
  • Page 26: View A Directory Code

    Step 2 Press 91 then press #, the system will show the total number of tenant. Note: A tenant directory with no name will not be included as a total number of tenant. Pach and Company Chapter 3 Page 19 AeGIS 8000 Series PROGRAMMING...
  • Page 27: Chapter 4. System's Operation

    20 and 21. TO CALL TO A VOICE MAIL OR EXTENSION Press the voice mail or extension number after the call is connected. Pach and Company Chapter 4 Page 20 AeGIS 8000 Series SYSTEM’S OPERATION...
  • Page 28 COUNTER CLOCKWISE to decrease the intensity. TO ADJUST SPEAKER AND MICROPHONE Turn the speaker and microphone adjustment pot (VR2), CLOCKWISE to VOLUME increase or COUNTER CLOCKWISE to decrease. Pach and Company Chapter 4 Page 21 AeGIS 8000 Series SYSTEM’S OPERATION...
  • Page 29: Chapter 5. Trouble Shooting Guide

    The system’s sound is ON and OFF while talking • The system is not full-duplex, if the environment is noise you will with the tenant. have this experience. • Speak further from the system. Pach and Company Chapter 5 Page 22 AeGIS 8000 Series TROUBLE SHOOTING GUIDE...
  • Page 30 • Check the connection between the keypad ribbon cable and the main board, the red line must be facing up. • Disconnect the keypad’s ribbon cable then reconnect it. Pach and Company Chapter 5 Page 23 AeGIS 8000 Series TROUBLE SHOOTING GUIDE...
  • Page 31: General Fcc Requirements

    GENERAL FCC REQUIREMENTS This equipment complies with Part 68 of the FCC rules. Located on the back of your AeGIS system is a label that contains, among other information, the FCC registration and ringer equivalence number (REN) for the sys- tem.
  • Page 32: Quick Reference Guide

    TO EXTEND THE TALK TIME: Tenant must press the # after the time-out warning beep, the talk time will be extended to another cycle. TO CALL INTO THE AeGIS 8000 SERIES: Dial the AeGIS phone number, you hear “ONE SHORT BEEP” if you are connected then press * to communicate with the visitor and press 9 or 8 (default setting to unlock the door 1 and door 2).

Table of Contents