Quick Wizard: Options - Daikin ERLQ004~008CAV3 Reference Manual

Altherma - low temperature split
Table of Contents

Advertisement

#
Code
Request is NOT available in leaving
water temperature control.
a
b
d
e
b
▪ a: Space heating/cooling control
▪ b: OFF
▪ c: On
▪ d: Heating demand (by ext RT or
▪ e: Pump operation
8.2.3

Quick wizard: Options

Domestic hot water settings
This chapter only applies to systems with a domestic hot water tank
installed:
▪ EHBH/X: an optional domestic hot water tank is available,
▪ EHVH/X: a domestic hot water tank is standard incorporated into
the indoor unit.
Following settings must be made accordingly.
#
Code
[A.2.2.1]
[E-05]
DHW operation:
▪ 0 (No): NOT installed. Default for
EHBH/X.
▪ 1 (Yes): Installed. Default for EHVH/X.
Remark: For EHVH/X, the domestic
hot water tank is by default installed.
Do NOT change this setting.
[A.2.2.3]
[E-07]
During domestic hot water preparation,
the heat pump can be assisted by an
electrical heater to ensure the domestic
hot water preparation even for high
desired tank temperatures.
DHW tank heater:
▪ 0 (Horizontal BSH): Installed at side of
the tank. Default for EHBH/X.
▪ 1
EHVH/X. The backup heater will also
be used in domestic hot water heating.
ERLQ004~008CAV3 + EHVH/X04+08S18CA + EHVH/X08S26CA
Daikin Altherma - Low Temperature Split
4P313775-1C – 2012.11
Description
c
c
b
c
(user interface)
RT)
Description
(Backup
heater):
Default
#
Code
[A.2.2.A]
[D-02]
Domestic hot water pump installed for...
Instant hot water
a
b
a Indoor unit
b Tank
c Domestic hot water pump
d Heater element
e Non‑return valve
f Shower
g Cold water
Thermostats and external sensors
See "5 Application guidelines" on page 8.
#
Code
[A.2.2.4]
[C-05]
for
8 Configuration
Description
The indoor unit offers the possibility to
connect a field supplied domestic hot
water pump (On/OFF type). Depending
on the installation and configuration on
the user interface, we distinguish its
functionality.
DHW pump:
▪ 0 (No)(default): NOT installed.
▪ 1 (Secondary rtrn): Installed for instant
hot water when water is tapped. The
end-user sets the operation timing
(weekly
schedule
time)
domestic hot water pump when it
should run. Control of this pump is
possible through the indoor unit.
▪ 2
(Disinf.
shunt):
Installed
disinfection.
It
runs
when
disinfection function of the domestic
hot water tank is running. No further
settings are needed.
See also illustrations below.
Disinfection
c
a
f
b
g
Description
Contact type main
In external room thermostat control, the
contact type of the optional room
thermostat or heat pump convector for
the main leaving water temperature zone
must
be
set.
See
"5
Application
guidelines" on page 8.
▪ 1 (Thermo ON/OFF): The connected
external room thermostat or heat
pump convector sends the heating or
cooling demand by the same signal as
it is connected to only 1 digital input
(preserved for the main leaving water
temperature zone) on the indoor unit
(X2M/1). Select this value in case of a
connection
to
the
heat
convector (FWXV).
▪ 2
(C/H
request)(default):
connected external room thermostat
sends separate heating and cooling
demand and is therefore connected to
the 2 digital input (preserved for the
main leaving water temperature zone)
on the indoor unit (X2M/1 and 2).
Select this value in case of connection
with the wired (EKRTWA) or wireless
(EKRTR1) room thermostat.
Installer reference guide
of
the
for
the
c
d
f
e
g
pump
The
45

Advertisement

Table of Contents
loading