Identification Label: Outdoor Unit; Identification Label: Indoor Unit; Possible Combinations Of Units And Options; List Of Options For Outdoor Unit - Daikin ERLQ004~008CAV3 Reference Manual

Altherma - low temperature split
Table of Contents

Advertisement

4.1.1

Identification label: Outdoor unit

Location
Model identification
Example: ER L Q 006 CA V3
Code
ER
European split outdoor pair heat pump
L
Low water temperature – ambient zone:
L=−10~−20°C
Q
Refrigerant R410A
006
Capacity class:
▪ 004=4.5 kW
▪ 006=6 kW
▪ 008=7.5 kW
CA
Series
V3
V3=1~, 230 V, 50 Hz
4.1.2

Identification label: Indoor unit

Location
Model identification
Example: E HV H 04 S 18 CA 3V
Code
E
European model
HV
HV=Floor-standing indoor unit with integrated tank
H
▪ H=Heating only
▪ X=Heating/cooling
ERLQ004~008CAV3 + EHVH/X04+08S18CA + EHVH/X08S26CA
Daikin Altherma - Low Temperature Split
4P313775-1C – 2012.11
Explanation
Description
4 About the units and options
Code
04
Capacity class:
▪ 04=4.5 kW
▪ 08=7.5 kW
▪ 16=16 kW
S
Integrated tank material:
S=Stainless steel
18
Integrated tank volume:
▪ 18=180 l
▪ 26=260 l
CA
Series
3V
Backup heater model
▪ 3V
▪ 9W
4.2
Possible combinations of units and
options
4.2.1

List of options for outdoor unit

Drain pan (EKDP008CA)
The drain pan is required to gather the drain from the outdoor unit.
The drain pan kit consists of:
▪ Drain pan
▪ Installation brackets
For installation instructions, see the installation manual of the drain
pan.
Drain pan heater (EKDPH008CA)
The drain pan heater is required to avoid freezing-up of the drain
pan.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the drain
pan heater.
INFORMATION
In case the drain pan heater is used, the jumper JP_DP on
the service PCB on the outdoor unit MUST be cut.
After cutting the jumper, you MUST reset the outdoor unit
to activate this function.
U-beams (EKFT008CA)
The U-beams are installation brackets on which the outdoor unit can
be installed.
It is recommended to install this option in colder regions with
possible low ambient temperatures or heavy snowfall.
For installation instructions, see the installation manual of the
outdoor unit.
4.2.2

List of options for indoor unit

User interface (EKRUCAL1, EKRUCAL2)
The user interface is delivered as an accessory with the unit. An
additional user interface is optionally available.
The additional user interface can be connected:
Description
Installer reference guide
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehvh/x04+08s18caEhvh/x08s26ca

Table of Contents