Basic Configuration; Quick Wizard: Language / Time And Date; Quick Wizard: Standard; Quick Wizard: Options - Daikin EGSQH10S18AA9W Installation Manual

Altherma ground source heat pump
Hide thumbs Also See for EGSQH10S18AA9W:
Table of Contents

Advertisement

Overview settings
01
00
00
01
15
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
Result: The value to be modified is now highlighted.
4 Modify the value by using the
Overview settings
01
00
00
01
20
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
5 Repeat previous steps if you have to modify other settings.
6 Push
to confirm the modification of the parameter.
7 At installer settings menu, press
Installer settings
The system will restart.
OK
Cancel
Confirm
Adjust
Result: The system will restart.
5.2

Basic configuration

5.2.1

Quick wizard: Language / time and date

#
Code
[A.1]
N/A
Language
[1]
N/A
Time and date
5.2.2

Quick wizard: Standard

Backup heater configuration
#
Code
[A.2.1.5]
[5-0D]
BUH type:
▪ 4 (3PN,(1/2)): 6 kW 3N~ 400 V
Space heating settings
#
Code
[A.2.1.7]
[C-07]
Unit temperature control:
▪ 0
operation is decided based on the
leaving water temperature.
▪ 1 (Ext RT control): Unit operation is
decided by the external thermostat.
▪ 2 (RT control): Unit operation is
decided
temperature of the user interface.
[A.2.1.B]
N/A
Only if there are 2 user interfaces:
User interface location:
▪ 0 (At unit)
▪ 1 (In room)(default)
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351747-1F – 2016.06
03
00
07
0b
0f
and
button.
03
00
07
0b
0f
to confirm the settings.
Description
Description
Description
(LWT
control)(default):
based
on
the
ambient
#
Code
[A.2.1.8]
[7-02]
[A.2.1.9]
[F-0D]
Brine freezing temperature
#
Code
[A.6.9]
[A‑04]
NOTICE
The setting brine freezing temperature can be modified
and the read out is correct in [A.6.9] Brine freezeup temp
ONLY after having accessed menu [A.8] Overview
settings.
This setting can ONLY be modified and/or saved and the
read out is ONLY correct if the communication between
hydro module and compressor module is present. The
communication between hydro module and compressor
module is NOT guaranteed and/or applicable if:
▪ error "U4" appears on the user interface,
▪ the heat pump module is connected to preferential kWh
rate power supply where power supply is interrupted
and preferential kWh rate power supply is activated.
Capacity boost
#
Code
Unit
N/A
[A‑03]
5.2.3

Quick wizard: Options

Domestic hot water settings
#
Code
N/A
[E-05]
5 Configuration
Description
Number of water temperature zones:
▪ 0 (1 LWT zone): Main
▪ 1 (2 LWT zones): Main + additional
Pump operation:
▪ 0 (Continuous): Continuous pump
operation, regardless of thermo ON or
OFF condition.
▪ 1 (Sample)(default): When thermo
OFF condition occurs, the pump runs
every 5  minutes and the water
temperature is checked. If the water
temperature is below target, unit
operation can start.
▪ 2 (Request): Pump operation based
on request. Example: Using a room
thermostat and thermostat creates
thermo ON/OFF condition.
Description
Brine freezeup temp
▪ 0: 0°C
▪ 1: –2°C
▪ 2: –4°C
▪ 3: –6°C
▪ 4: –8°C
▪ 5: –10°C
▪ 6: –12°C
▪ 7 (default): –14°C
Description
Compressor frequency
▪ 0 (default): normal
▪ 1: boost
Description
DHW operation:
▪ 0: N/A
▪ 1 (Yes): Installed
Installation manual
15