11.2 Inspection

● Rocker arm outer diameter
Standard in (mm)
0.1570-0.1573 (3.988-3.996)
● Rocker arm inner diameter of inlet/exhaust valve
Standard in (mm)
0.1575-0.1579 (4.000-4.012)
● Inner diameter of rocker arm bearing
Standard in (mm)
0.1575-0.1579 4.000-4.012
Service limit in (mm)
0.1555 (3.950)
Service limit in (mm)
0.2598 (4.050)
Service limit in (mm)
0.2598 in 4.050