7.2 Inspection

a. Control panel
● AC receptacle
Check the electrode contact disk inside receptacle; if it is burnt or discolored, replace for it.
● DC receptacle
After checking the fuse, connect both terminals of the receptacle with a jumper wire to short. There must
be continuity between the lead wire terminals with the circuit protector ON. Replace the DC receptacle if
there is no continuity.
● Smart switch
There should be continuity with the switch ON, and no continuity with the switch OFF.
● Ignition Module
Pull off the 10P receptacle from the module, measure the resistance by connecting one testing pen with
the metal outer case of engine, and the other testing pen with the 10P connector.
Color
Blue
Orange
Yellow
Yellow/Green
Green
Red
Circuit unit
Primary coil of the ignition coil
Oil level alarm
Trigger coil
Ground wire
Igniter unit power coil winding
Engine switch
Standard resistance
There should be no continuity with correct
There should be no continuity with the
switch ON, continuity with the switch OFF
35
0.8-1.3Ω
oil level
80-130Ω
Continuity
0.5-0.7Ω