If   y ou   a re   u sing   a n   o lder   t ransceiver   o r   t ransmitters   w ithout   t ime   d elay,   w e   r ecommend   t o   c onnect  
the  PA  in  such  a  way  that  the  transmit/receive  switch  (foot  switch  for  example)  is  connected  with  
the  KEY  IN  socket  of  the  amplifier.  The  KEY  OUT  socket  is  to  be  connected  with  the  PTT  socket  at  
the   t ransceiver.  
The   amplifier   is   equipped   with   safety   devices,   which   ensure   that   the   output   relay   is   not   switched  
under   p ower   m istakenly   ( hot   s witching).  
KEY   I N    
 
KEY   O UT  
 
 
4.4.
Main   S upply  
Be  sure  you  got  PA  with  properly  terminated  line  cable,  corresponding  with  your  power  system's  
outlet.  If  not,  contact  your  dealer.  In  such  a  case  you  should  make  the  necessary  changes  using  a  
licensed   e lectrician.    
 
Be   s ure   t hat   y our   p ower   s ystem   i s   c orrectly   w ired   a nd   p roperly   r ated!   T o   u se   a dequately   s ized   a nd  
connected   g rounding   s ystem   i s   a lso   v ery   i mportant.  
 
4.5.
Cooling  
 
The   a mplifier   m ust   b e   i nstalled   i n   s uch   a   w ay   t hat   f ree   f low   o f   h ot   a ir   f rom   t he   t ube   i s   a llowed.   D o  
not   o bstruct   a ir   i ntake   a nd   e xhaust   a reas   o f   t he   P A.  
 
The   centrifugal   blower   provides   the   necessary   cooling   of   the   amplifier,   even   during   long   contests.  
The   b lower   i s   a ctivated   b y   s witching   t he   P A   o n   a nd   i t   i s   t urned   o ff   w hen   c ooling   i s   f inished   ( approx.   1 -­‐
5  min  after  switching  off  the  PA  depending  on  the  temperature  of  the  tube).  Blower  speed  (2  steps)    
is   s etting   a utomatically   a ccording   t o   t he   t ube   t emperature.  
 
 
CAUTION  
RCA   P hono   -­‐   I nput   s ignal   P TT   s witching   v oltage   /   c urrent   -­‐     5 V   / 2mA)  
RCA   P hono   -­‐   O utput   s ignal   P TT   ( maximum   s witching   o f   3 0V   /   5
CAUTION  
WARNING!  
CAUTION  
 
 
 
 
 
Detailed   v iew   o n   t he   t ube   a nd   b lower   a rea.  
  A ntenna   s witch   ( above)   i s   i nstalled   i nside   t he    
metal   b ox.  
0mA)  
 
 