Lewmar AutoAnchor 550 Operation Manual page 21

Chaincounter and windlass control
Hide thumbs Also See for AutoAnchor 550:
Table of Contents

Advertisement

C
S
ABLE
PECIFICATIONS
Cable from AA550 Console to the Sensor: Belden 9501 (AWG24)
or equivalent, tinned, 2 core, screened.
Cable from AA550 Console to batteries and solenoids:
All battery and motor cables must be ring type.
This specification is based on the total cable length measured from the bat-
tery to the console plus from the console to the solenoids.
Where the total length is less than 33 ft (10m) - AWG16 (1.5mm
Where the total length is between 33 ft (10m) and 66 ft (20m) - AWG14
(2.0mm
)
2
Where the total length is between 66 ft (20m) and 132 ft (40m) - AWG12
(3.0mm
)
2
For lengths greater than this refer to your supplier.
M
AINTENANCE
The AA550 does not contain any user servicable parts. User mainte-
nance is limited to :
• Checking all cables and connections for signs of wear or damage
and replacing them as necessary
• Checking the sensor head is not worn and has not moved out of
alignment with the magnet and replacing the sensor if necessary
• Checking the magnet is not worn or corroded and replacing the
magnet if necessary
Note: Do not use chemical or abrasive materials to clean the console
unit. If it is dirty wipe it with a clean damp cloth. Avoid wiping the
display screen with a dry cloth as this could scratch the screen.