Lewmar AutoAnchor 550 Operation Manual page 20

Chaincounter and windlass control
Hide thumbs Also See for AutoAnchor 550:
Table of Contents

Advertisement

12. The windlass
does not stop exactly
at the preset point.
13. AA550 counts
when the windlass is
not turning or counts
erratically displaying
a large number eg
8888.
14. AA550 beeps
when it is turned off
or locked.
This is not a fault. Stopping is accurate to
+1 chainwheel revolution. The chainwheel
may run on slightly with momentum.
The sensor could be damaged, incorrect
cable may be fitted, or the AA550 may have
been subject to external interference - RF
or electrical. Check that the sensor cable
is not damaged and that the cable fitted is
Beldon 9501 or equivalent, 2 core, tinned,
copper, screened, as specified in the instruc-
tions. Check for external interference on
the boat eg damaged or loose RF cables or
aerials or other instruments that may not be
working correctly or have been damaged by
electrical interference including lightning.
Anchor rode is running through the
windlass. Check if the windlass is being
operated using the deck switches or a
remote control. If not, check the windlass
and anchor is secured.