Oki OKIOFFICE 1200 Field Engineering Manual page 77

Table of Contents

Advertisement

Unique Switch e:2 - Scanner
Initial
Switch
Setting
7
0
Factory use only
6
1
Factory use only
5
0
Continuous lighting of the
lamp for CCD adjustment
(Only for OKIOFFICE 1600)
0: No
1: Yes
4
0
Initial setting of Copy
resolution
(Only for OKIOFFICE 1600)
0: 600 × 400 dpi
1: 600 × 600 dpi
3
0
Factory use only
2
0
Factory use only
1
0
Mirror carriage home position
0: FBS
1: ADF
0
1
Mirror carriage home position
0: Fixed
1: Variable
Note: These settings effect after turn the power switch off/on.
Unique Switch e:3 --- Factory use only
Unique Switch e:4 - Scanner
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Leading edge document
margin adjustment for
2
0
copying using ADF or FBS
1
0
(Only for OKIOFFICE 1600)
0
0
Each setting changes
by 0.847mm.
Adjust
Note: Initial setting for OKIOFFICE 1600 is "0".
Setting at "1", the lamp continues to light when the
setting of Background Level.
After using this switch, it must be set at "0" after turn
the power off/on.
When set to "1", copy resolution changes into 600 ×
600 dpi.
This switch is only effective when the unique switch
E:2 bit 0 is set at "0".
Determines the Mirror carriage home position.
Determines the Mirror carriage home position.
Adjust
Switch
3-50
Usage/Comments
Usage/Comments
3 2 1 0
Settings
1 1 1 1
12.705 mm
1 1 1 0
11.858 mm
|
|
|
|
0 0 1 0
1.694 mm
0 0 0 1
0.847 mm
0 0 0 0
0 mm