Machine Parameter B:1
Initial
Switch
Setting
7
*
Leading edge document
margin adjustment
6
*
(ADF)
5
*
4
*
Adjusts the leading edge
3
*
margin from the mirror
2
*
carriage passes End Sensor
1
*
to the start of the scanning
0
*
position.
Each setting changes
by 0.847mm.
Note: These values are
factory set and should not be
adjusted unless instructed by
a technical representative.
Machine Parameter B:2
Initial
Switch
Setting
7
0
ADF scanner registration
adjustment (Horizontal)
6
0
5
0
Adjusts the start point to scan
4
0
the document.
3
0
The plus setting increase the
2
0
left margin and the minus
1
0
setting decrease it.
0
0
Each setting changes by
0.5 mm.
Adjust
Switch 76543210
Adjust
Switch 76543210
3-7
Usage/Comments
Settings
00000000
0.00 mm
00000001
0.847 mm
00000010
1.694 mm
34.727 mm ← Initial setting
00101001
36.421 mm ← Initial setting
00101011
11111110
215.138 mm
11111111
215.985 mm
Usage/Comments
Settings
00000111
3.5 mm
00000110
3.0 mm
00000101
2.5 mm
00000100
2.0 mm
1.5 mm ← Initial setting
00000011
00000010
1.0 mm
00000001
0.5 mm
standard ← Initial setting
00000000
10000001
-0.5 mm
10000010
-1.0 mm
10000011
-1.5 mm
10000100
-2.0 mm
10000101
-2.5 mm
10000110
-3.0 mm
10000111
-3.5 mm