Memory Switch B:2 - Transmission
Initial
Switch
Setting
7
0
Data signaling rate (DCS)
0: V.17
1: V.33
6
0
Forced received print when
transmitting from memory
0: No
1: Yes
5
0
European date format on TTI
0: No
1: Yes
4
1
TTI transmit
0: No
1: Yes
3
0
ECM response time
0: 3 sec
1: 4.8 sec
2
0
ECM error retransmit time
0: 200 ms
1: 400 ms
1
0
Interval between DIS and DCS
0
0
Switch 1
Switch 0
Memory Switch B:3 - Transmission
Initial
Switch
Setting
7
0
ANSam detection
(Only for OKIOFFICE 1600)
0: Yes
1: No
6
0
V.34 transmission
(Only for OKIOFFICE 1600)
0: Yes
1: No
5
0
Factory use only
4
0
ECM mode
0: On
1: Off
3
0
Retransmit automatically
when receiving RTN/PIN
signals
0: Yes
1: No
2
1
Factory use only
1
0
Factory use only
0
0
Factory use only
Memory Switch B:4 --- Factory use only
Adjust
Determines communication protocol.
Will force a remote OKIOFFICE machine with
memory receive capabilities to print directly. This
switch will prevent a memory overflow error at the
remote unit.
Assigns European date format to the transmitted
TTI.
(Example: 29 May 1997)
When set at "0", transmission of the TTI is disabled.
(Note: Turning TTI transmission off may violate
local or federal regulations.)
The time limit to receive the response signal for the
ECM post message.
The time limit before the ECM error is
retransmitted.
0 ms 500 ms 1000 ms 1500 ms
0
0
1
0
1
0
Adjust
During the V8 handshake, if some noise disturbs
the handshake and an error occurs, set to "1".
Individual setting for V.34 transmission.
Determines ECM mode. ECM mode reduces
document memory and may lengthen transmission
and reception times.
When set to "1", retransmission disables
automatically if receiving RTN/PIN signals.