Machine Parameter F:1
Initial
Switch
Setting
7
*
Adjustment of the scanning
stretching and squeezing for
6
*
ADF. (Vertical)
5
*
4
*
The plus setting stretch the
3
*
image data and the minus
2
*
setting squeeze it.
1
*
Each setting changes by
0
*
0.1%
Machine Parameter F:2
Initial
Switch
Setting
7
*
Adjustment of the scanning
stretching and squeezing for
6
*
FBS. (Vertical)
5
*
4
*
The plus setting stretch the
3
*
image data and the minus
2
*
setting squeeze it.
1
*
Each setting changes by
0
*
0.1%
Machine Parameter F:3 ∼ ∼ ∼ ∼ G:5 --- Factory use only
Adjust
Switch 76543210
Adjust
Switch 76543210
3-13
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00100000
3.2 %
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
00000000
Initial setting
:
-0.5 % ← Initial setting
10000101
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10100000
-3.2 %
:
10111000
-12.7 %
Usage/Comments
Settings
01111111
12.7 % Maximum
:
00100000
3.2 %
:
00011000
2.4 %
:
00010000
1.6 %
:
00001000
0.8 %
:
00000000
Initial setting
:
-0.7 % ← Initial setting
10000111
10001000
-0.8 %
:
10010000
-1.6 %
:
10011000
-2.4 %
:
10100000
-3.2 %
:
10111000
-12.7 %