Usb Com Interface Set-Up - Datalogic Magellan 3200VSi Product Reference Manual

On-counter vertical presentation scanner
Hide thumbs Also See for Magellan 3200VSi:
Table of Contents

Advertisement

Keyboard Wedge — cont.
Intercharacter Delay
START / END
One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the
system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable
from 00 to 99 in 10msec increments.
To configure this feature, scan the "START/END" bar code above to place the unit in Programming Mode, then the "Set Intercharac-
ter Delay," followed by the three digits (zero padded) from the Alphanumeric table in
ing your desired length. Exit programming mode by again scanning the "START/END" bar code above/

USB COM Interface Set-up

The scanner has two USB COM interfaces, USB COM and USB COM DL (Datalogic). The
Datalogic USB-COM driver works for both USB COM interfaces.
Before plugging your scanner into the Host PC, please ensure you have already copied the exe-
cutable DLS-USB-COM driver file to your PC and that the scanner's interface is set to USB
COM or USB COM DL. The DLS-USB-COM driver is provided by Datalogic or downloaded
from the Datalogic Scanning website listed on the back cover of this manual.
1. Execute the DLS-USB-COM driver file.
2. When the scanner is first plugged into the PC, Windows will bring up the "Found New
3. The installation is complete.
Product Reference Guide
PROGRAMMING bar codes
DEFAULT SETTING FOR THIS FEATURE:
Hardware" message.
Appendix C, Alpha-Numeric Pad
00 (No Delay)
Set Intercharacter Delay
USB COM Interface Set-up
represent-
71

Hide quick links:

Advertisement

Table of Contents
loading