Fig. 118
Burner
60, 70 and 80
Models Only
Fig. 120
Pilot Hood
Fig. 122
RH Side Insulation
Insulation Carrier
Bracket
Supplied By www.heating spares.co Tel. 0161 620 6677
Pilot Injector
Sealing Washer
Fig. 121
Electrode
Electrode Lead
Inlet Adaptor
11.0 Changing Components
11.10
Burner (Fig. 118)
1. Remove the burner assembly by pulling it
forward.
2. Fit new burner and re-assemble all components
in reverse order of dismantling.
11.11
Burner Injector (Fig. 120)
1. Release and remove the burner injector which
is screwed into the burner feed manifold.
Fig. 119
2. Fit the new burner injector ensuring that the
copper washer is in position. Tighten the injector
fully.
3. Re-assemble all components in reverse order.
11.12
Pilot Burner Injector (Fig. 121)
1. Remove the right hand side insulation carrier
bracket by releasing the screw. Remove the side
insulation panel (Fig. 122).
2. Release the screw securing the pilot hood and
remove. Carefully remove the pilot injector. Fit the
new pilot injector ensuring the new sealing washer
is in position. Tighten the injector fully.
3. Re-assemble all components in reverse order.
11.13
Gas Manifold (Fig. 123)
1. Undo the
panel down.
2. Pull the electrode lead off the electrode.
3. Remove the right hand side insulation carrier
bracket by slackening the screw. Remove the
burner. Remove the side insulation panel
(Fig. 122).
4. Undo the three screws securing the brass inlet
adaptor to the manifold.
5. Remove the two screws securing the manifold
from the inside of the combustion box and slide
the manifold forward from under the two rear
locating studs, taking care not to lose the gasket.
Gas Manifold
6. Remove the electrode
7. Replace all ancillary components onto manifold
and replace manifold by sliding rear edge
backwards under the two rear locating studs and
securing from inside the combustion box using the
two screws previously removed. Ensure that the
sealing gasket is properly positioned and
undamaged.
Fig. 123
1
/
turn screws and drop the facia
4