Baxi Solo 3 Installation And Servicing Instructions page 16

Baxi solo 3 pfl system, wall mounted powered flue system boiler, gas fired central heating unit
Table of Contents

Advertisement

6.0 Installation
6.3
Fan Outlet Restrictor
5 Pin Electrical Plug
Rear Flue only up to 500mm (19
5
/
in)
8
1. Release the four latches holding the
combustion box door (Fig 16). Remove the
combustion box door by pulling forward (Fig. 16).
Fig. 15
2. Release the 5-pin electrical plug connecting
Flexible Tubes
the pressure switch and fan (Fig. 15). Withdraw
Fan Assembly
the fan assembly by pulling forwards from the
top edge (Fig. 16).
3. Take the restrictor (supplied in the kit of
parts), check that the number stamped on the
restrictor matches the appliance (e.g. 50
stamped on the restrictor is for 50 PF appliance)
4. Fit the restrictor to the fan outlet flange,
bending the 3 lugs equally ensuring the restrictor
seals against the fan outlet flange (Fig. 17).
Fig. 16
5. Re-assemble the fan assembly and
combustion box door ensuring that the flexible
Combustion Box Door
tubes from the fan unit to the pressure switch are
routed correctly and that they are not kinked or
flattened (Fig. 16).
Fan Outlet Restrictor
Fan Outlet Flange
Fig. 17
16
Supplied By www.heating spares.co Tel. 0161 620 6677