Fixing Template
Y
5 mm
Minimum Clearance
From Outercase To
Edge Of Template
X
Fixing Points marked X and Y can be
used for additional securing of the
combustion box to the wall.
Points X must be used when optional
security bolts are fitted
X
Fig. 14c
GAS SUPPLY
100 mm
Minimum
Clearance
Supplied By www.heating spares.co Tel. 0161 620 6677
50 mm
Minimum Clearance
Vertical Flue
Centre Line
Horizontal Flue
Centre Line
Minimum Clearance
From Outercase To
Edge Of Template
Solo 3 System Boiler
TEMPLATE
Boiler
Center Line
Side And Top
Flue Template
FLOW
RETURN
6.0 Installation
6.2
1. Remove the fixing template (Fig. 14c) from the
carton.
2. After considering the site requirements
(see Section 5.2) position the template on the
wall ensuring it is level both horizontally and
vertically. If it is desired that the appliance is
positioned centrally between two points, mark
the wall accordingly and align the template
centreline with this mark.
Y
3. Mark at least four suitable fixing holes for the
wall plate. Preferably the two at either side of the
5 mm
flue airbox should be used. Fixing points X and Y
can be used for additional securing of the
combustion box assembly to the wall. Points X
must be used when the optional security kit is
Profile of
used.
Outercase
4. Drill the anchorage holes 63mm (2
X
to accept suitable wall plugs.
5. Mark the centre of the flue hole (rear exit). For
side exit, mark as shown. If required, mark the
position of the gas, water and pressure relief
discharge pipes. Remove the template.
6. Cut the hole for the flue (minimum diameter
X
107mm).
7. For rear flue applications continue as
described in Section 6.4. Side flue installations
are covered in Section 6.7.
PRESSURE
RELIEF
Initial Preparation (continued)
1
/
in) deep
2
15