6.0 Installation
6.5
Assembly of Rear Flue
1. Remove the rear air box blanking plate from
the wall plate by releasing the three screws
(Fig. 25).
2. Remove the blanking cap at the rear of the
turret, by pushing and turning anti-clockwise to
release the bayonet fitting (Fig. 25).
Fig. 25
3. Locate the swaged end of the flue duct over
the bayonet fitting on the turret, taking care not to
damage the 'O' ring. Lock the flue duct in place by
pressing in and turning clockwise (Fig. 26).
4. Engage the bayonet slots of the air duct over
the location lugs on the back plate opening and
press and turn clockwise to secure the air duct to
the back plate (Fig. 27).
5. In order to increase security of the flue, the
Fig. 26
bayonet tags may be deformed to secure the flue
in position.
6. Take the flue terminal assembly and engage
on the flue and air ducts. Slide the flues together
to the desired wall thickness.
7. Tape the outer duct sections together with the
tape provided ensuring a good seal is made
(Fig. 27a).