J3 Connector - JLG 3369LE Service Maintenance Manual

Table of Contents

Advertisement

PIN
TAGNAME
38
4AWR
39
OSAX
40
DO22
PIN
TAGNAME
1
DO23
2
DO24
3
DO25
4
DO26
5
DI12
6
DI13
7
IGN
8
ORSTO
9
ORSET
10
IGN
11
FLU
12
FLD
13
FRU
14
FRD
15
RLU
16
RLD
17
RRU
18
RRD
19
GMST
20
GINH
21
GFLT
22
GNDE
23
GND
24
GND
3121122
Table 5-12. J2 Connector
FUNCTION
4 Wheel Assist Reverse Solenoid Valve
Oscillating Axle Solenoid Valves
Spare High-Side Digital Otput 22 (12V, 5A)
Table 5-13. J3 Connector
FUNCTION
High-Side Digital Output 23 (12V, 5A)
High-Side Digital Output 24 (12V, 5A)
High-Side Digital Output 25 (12V, 5A)
High-Side Digital Output 26 (12V, 5A)
High-Sensing Digital Input 12
High-Sensing Digital Input 13
Ignition Power (+12V)
Outrigger Set Input
Outrigger Stow Input
Ignition Power (+12V)
Front-Left O/R Up Solenoid Valve
Front-Left O/R Down Solenoid Valve
Front-Right O/R Up Solenoid Valve
Front-Right O/R Down Solenoid Valve
Rear-Left O/R Up Solenoid Valve
Rear-Left O/R Down Solenoid Valve
Rear-Right O/R Up Solenoid Valve
Front-Right O/R Down Solenoid Valve
Generator Manual Start (to J5-13)
Generator Inhibit Start (to J1-21)
Generator Fault LED (to J5-14)
Ground EMS (from J5-2; 500mA Limit)
Ground
Ground
– JLG Lift –
SECTION 5 - JLG CONTROL SYSTEM
TYPE
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
TYPE
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
INPUT
DIGITAL
INPUT
POWER
OUTPUT
DIGITAL
INPUT
DIGITAL
INPUT
POWER
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
DIGITAL
OUTPUT
POWER
POWER
POWER
POWER
OUTPUT
POWER
OUTPUT
POWER
OUTPUT
I/O
I/O
I/O
5-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M33694069leM4069