SECTION 3 - CHASSIS & SCISSOR ARMS
4. Cut and remove the Wire Ties holding the Harness
label to the harness. Next, remove the Wire Ties so
that the cable sleeve can be moved, exposing the
conductors of the harness.
3-20
5. Cut wire 106 going to the Engine/Generator Control-
ler after the existing connection point and install the
conductors that lead to the new inline fuse holder.
Use insulated butt splice connectors for these con-
ductors.
6. Re-install the harness with the new fuse in place.
7. Reconnect the lift and APU start battery. The APU is
now ready for use.