Amp Connector; Spec Connectors; Assembly - JLG 340AJ Service And Maintenance Manual

Hide thumbs Also See for 340AJ:
Table of Contents

Advertisement

MIL-C-5015 SPEC CONNECTORS
Crown Connector Inc's recommendation is to not use dielec-
tric grease for this series connector. For similar model series
connectors, the manufacturer should be contacted for confir-
mation before applying dielectric grease. A typical application
for this connector is on David Clark Intercom connections in
Aerial Work Platforms.
3121259
SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS

7.4 AMP CONNECTOR

Assembly

Check to be sure the wedge lock is in the open, or as-shipped,
position (See Figure 7-7.). Proceed as follows:
Figure 7-7. Connector Assembly Figure 1
1. To insert a contact, push it straight into the appropriate
circuit cavity as far as it will go (See Figure 7-9.).
2. Pull back on the contact wire with a force of 1 or 2 lbs. to
be sure the retention fingers are holding the contact
(See Figure 7-9.).
Figure 7-8. AMP Connector
– JLG Lift –
7-7