Pharmacode
Read the following symbols to enable/disable Pharmacode settings:
Pharmacode Off (Default)
Pharmacode On
Pharmacode by ESP
Fixed Symbol Length Status
When enabled, the imager will check the symbol length against the symbol length field. If
disabled, any length will be considered valid.
Symbol Length
Specifies the exact number of bars that must be present for the imager to recognize and
decode the Pharmacode symbol.
Minimum Bars
Sets the minimum number of bars that a Pharmacode symbol must have to be considered
valid.
Bar Width Status
If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set
to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be
considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to
determine whether the bars are narrow or wide. The Bar Width Status setting will be
ignored when the imager is able to tell the difference between the narrow and the wide
bars.