MEITRACK MVT380 User Guide
10 (OUT2)
Yellow
11 (OUT3)
Yellow
12 (OUT4)
Yellow
13 (OUT5)
Yellow
14 (AD2)
Blue
15 (GND)
Black
16 (POWER)
Red
8.1.1 Power Cable/Ground Wire (PIN7, PIN8)
Connect the power cable (red) and ground wire (black) to the positive and negative electrodes of the vehicle battery
respectively.
Copyright © 2015 Meitrack Group All rights reserved.
power supply.
Output 2
Valid: low level (0 V)
Invalid: open drain
Maximum voltage for output open drain (invalid): 45 V
Maximum current for output low voltage (valid): 500 mA
Connects to an external relay to remotely cut off the vehicle fuel cable or engine
power supply.
Output 3
Valid: low level (0 V)
Invalid: open drain
Maximum voltage for output open drain (invalid): 45 V
Maximum current for output low voltage (valid): 500 mA
Connects to an external relay to remotely cut off the vehicle fuel cable or engine
power supply.
Output 4
Valid: low level (0 V)
Invalid: open drain
Maximum voltage for output open drain (invalid): 45 V
Maximum current for output low voltage (valid): 500 mA
Connects to an external relay to remotely cut off the vehicle fuel cable or engine
power supply.
Output 5
Valid: low level (0 V)
Invalid: open drain
Maximum voltage for output open drain (invalid): 45 V
Maximum current for output low voltage (valid): 500 mA
Connects to an external relay to remotely cut off the vehicle fuel cable or engine
power supply.
Analog input 2 with 10-bit resolution and valid voltage of 0–6 V.
Connects to an external sensor, such as the fuel sensor and temperature sensor.
Ground wire
It can be used as a ground wire connected to an analog sensor.
Positive pole of the power output. The output voltage is equal to that of pin 8.
Supplies power to an external device.
- 13 -