Lexmark FORMS 249X Technical Reference page 165

Forms printer
Table of Contents

Advertisement

Invalid Interleaved 2of5 command:
<x
1B5B66
- barcode setup command prefix
0600
- setup data length (low byte first) - x0006, 6
B6
- barcode type = Interleaved 2of5
00
- module width = default
00
- space width adjustment = default
4003
- height (low byte first) - x0340 = 832 = 0.385
inches
00
- control byte: check digit from host, print
human readable character
1B5B70
- barcode data transfer command prefix
0400
- data transfer length (low byte first) -
x0004, 4
>058$ ...
Four characters are specified in the Data Transfer Command. The first three
characters, "058", are in the character set for Interleaved 2of5. The fourth
character,' $', is not valid for Interleaved 2of5.
UPC-A
UPC-A is an all-numeric, fixed-length symbology.
k value:
m value:
s value:
minimum v1, v2 values:
c parameter:
n1 value (b0 = 0):
n1 value (b0 = 1):
n2 value:
183, xB7
0 to 4, x00 to x04
-3 to 3, xFD to x03
x0E, x01 (248x)
x20, x01 (249x)
available functions:
b0, check digit
b1, human readable
b2, flag character position
12, x0C
11, x0B
0, x00
Section 8: Barcodes