19 (GT 1200 only)
Installation with TAS: Panel packages FM 126 to FM 134 and tank package BH 103 or BH 104
Fitting the DHW sensor and electrical connection of the TAS
The power supply cable is fitted with a foolproof system (clip and round pin) to prevent incorrect connection which would damage the TAS.
Pass the sensor cable and the TAS anode cable into the sheath on the DHW tank.
Connect the clip to the pin on the trap.
Fit the round pin directly onto the threaded section of the TAS anode. Hold the pin in place using the serrated washer and the nut.
Introduce the DHW sensor into the holding lug on the tank inspection trap. Make the electrical connection in compliance with the control
panel instructions.
Fit the thermal insulation.
Hook on the front panel of the hot water tank.
02/11/05 - 300003690-001-A
GT/GTU 120 - GT/GTU 1200
Mounting GT 120 - GT 1200